L P V- 6 0 60W Single Output Switching Power Supply series Features : Constant voltage design Universal AC input / Full range Fully encapsulated with IP67 level (Note.8) Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage Fully isolated plastic case Cooling by free air convection UL1310 Class 2 power unit Pass LPS 100% full load burn-in test Low cost, high reliability Suitable for LED lighting and moving sign applications (Note.7) 2 years warranty LPS IP67 SPECIFICATION MODEL OUTPUT ( except for 5V,48V ) LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 DC VOLTAGE 5V 12V 15V 24V 36V 48V RATED CURRENT 8A 5A 4A 2.5A 1.67A 1.25A CURRENT RANGE 0 ~ 8A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.67A 0 ~ 1.25A RATED POWER 40W 60W 60W 60W 60W 60W 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE TOLERANCE Note.3 8.0% LINE REGULATION 1.0% SETUP, RISE TIME 2.0% Note.6 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V) 50ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.4 90 ~ 264VAC 16ms/115VAC at full load 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 76% AC CURRENT INRUSH CURRENT(max.) 1.2A/115VAC 1A/230VAC COLD START 30A/115VAC LEAKAGE CURRENT 0.25mA / 240VAC OVER CURRENT PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION LPV-60-48 5.0% 6.0% LOAD REGULATION INPUT ( for 48V only) 83% 83% 86% 86% 86% 41.4 ~ 48.6V 55.2 ~ 64.8V 60A/230VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL879, UL1310 Class 2(except for LPV-60-5), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), IP67 approved ; design refer to TUV EN60950-1, EN61347-2-13 WITHSTAND VOLTAGE I/P-O/P:3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B OTHERS HARMONIC CURRENT Compliance to EN61000-3-2 Class A, EN61000-3-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 732Khrs min. MIL-HDBK-217F (25 ) 162.5*42.5*32mm (L*W*H) 0.4Kg; 32pcs/13.8Kg/0.56CUFT DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. In the European market this product is only suitable for LED lighting applications that don't have to comply with the harmonic current requirements of EN61000-3-2 Class C. 8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute. File Name:LPV-60-SPEC 2011-01-03 http://store.iiic.cc/ L P V- 6 0 60W Single Output Switching Power Supply Mechanical Specification Case No. 976A 162.5 600 30 series Unit:mm 600 30 18AWG 3.6 16AWG 42.5 3.6 3.5 AC/N(Blue) AC/L(Brown) 3.5 3.5 +V(Red) -V(Black) 32 3.5 Recommend Mounting Direction Block Diagram fosc : 65KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. +V -V DETECTION CIRCUIT PWM CONTROL O.V.P. Derating Curve Static Characteristics Ta=25 100 100 230VAC 90 80 80 70 115VAC LOAD (%) LOAD (%) 60 40 20 -30 -15 0 15 30 40 50 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz AMBIENT TEMPERATURE ( ) File Name:LPV-60-SPEC 2011-01-03 http://store.iiic.cc/