G 46
600-750V DC SQUARE-BODY/SPECIAL PURPOSE
Dimensions
SIZE CURRENT
RATING
IN(A)
INTERRUPTING
RATING CATALOG NUMBER (1) REF.
NUMBER
APPLICATIONS DATA
123
500
500
WATTS LOSS
0.8 ININ
@ 750V DC
100kA
L/R = 100ms
@ 900V DC
100kA
L/R = 40ms
51
51
93.5
93.5
CC 7,5 gRC 123 EF 0500
CC 7,5 gRC 123 TTF 0500
M089389
D090439
MAXIMUM l2t
@900V=L/R 40ms
Ip=10INIp=50IN
5x106
5x106
110
6
110
6
630
700
750
630
700
750
@ 750V DC
100kA
L/R = 50ms
7.5 106
10 106
10 106
7.5 106
10 106
10 106
1.5 106
210
6
210
6
1.5 106
210
6
210
6
74
82
82
74
82
82
CC 7,5 gRB 123 EF 0630
CC 7,5 gRB 123 EF 0700
CC 7,5 gRB 123 EF 0750
CC 7,5 gRB 123 TTF 0630
CC 7,5 gRB 123 TTF 0700
CC 7,5 gRD 123 TTF 0750
B098556
Q078191
F220943
C098557
F090441
H220945
maximum 12t(A2s)
@800V = L/R 40ms
Ip=10 INIp=50 IN
maximum 12t(A2s)
@660V = L/R 30ms
Ip=10 INIp=50 IN
800
800
@ 660V DC
100kA
L/R = 50ms
12.15x106
12.15x106
2.6 106
2.6 106
90
90
CC 6.6 gRB 123 EF 0800
CC 6.6 gRB 123 TTF 0800
G220944
J220946
CC.... 123 E ...
40
171
13
CC.... 123 TTF ...
M12
Tapped
9mm deep
90.5
28
75
87
75
75
87 90.5
Weight: 1,820 g
Weight: 1,800 g
6
See
page G47
75
SIZE: 123
206
129
131
129
CC 7.5gRC 500 Amp
750vdc@100kA
L/R=100mSec
900vdc at 100kA
L/R=40mSec
CC 7.5gRB, gRD
630 to 750 Amp
750vdc@100kA
L/R=50mSec
CC 6.6gRB 800 Amp
660vdc@100kA
L/R=50mSec
Ratings Features/Benefits
CC 7.5gRC 500 Amp
Blown Fuse indicator
Square ceramic body
Full range D.C. operation
Bladed and tapped versions
standard
CC 7.5gRC, gRD
Blown Fuse indicator
Square ceramic body
Full range D.C. operation
Bladed and tapped versions
standard
CC 6.6gRB, gRD
Blown Fuse indicator
Square ceramic body
Full range D.C. operation
Bladed and tapped versions
standard
G 47
G
600-750V DC SQUARE-BODY/SPECIAL PURPOSE
DC Application Data Peak Arc voltage vs. working voltage
Time vs. current characteristics
Above: Curves indicate maximum permissible value of time
constant L/R as a function of DC working voltage.
Max. AC voltage (50/60 Hz): 1250V with interrupting rating
of 170kA.
1-L/R = 100ms
2-L/R = 40ms
Above: Curves indicate for various time constants L/R the peak
arc voltage which may appear across fuse terminals, vs. DC
working voltage.
Above: Curves indicate, for each rated current, pre-arcing time
vs. R.M.S. pre-arcing current.
Current 630 550 Maximum
rating 700 600 operating
(A) 750 600 current
800 650 (A)
7% tolerance for mean
pre-arcing current
+
-
10 3
10 4
10 2
10
1
10-1
10-2
10-3
10-4
t (s)
I (A)
10 310 4
10 210 5
a=130
A2=0.6
B1=1.25
B2=0.6
Cf3=0.8
90
80
70
60
50
40
30
20
10
0
500
600
700
800
900
1000
1100
L/R (ms)
U (V)
2: curve gRB-gRD
3: curve gRB ( 800 A )
2400
2000
1600
1200
800
400
0
0
200
400
600
800
1000
Um(V)
U (V)
1
2
31
2
500
630
700-750
800