Cylindrical photoelectric sensors in M18 plastic or brass housings E3F2 * Complete sensor portfolio in plastic and metal housing * IP67, IP69K for highest water resistance * High immunity against electro-magnetic noise and ambient light * Special beam models * High power LED to compensate for dirt and misalignment Performance and portfolio variety Sensing method *1 *2 Plastic Metal 90 Optics Through-beam 7m 7m - 3m Retro-reflective 4m 4m 2m 1m Diffuse-reflective 1m 1m 0.3 m 0.3 m 0.1 m 0.1 m Diffuse-reflective (background suppression) *1 *2 Shape AC power supply SUS types see seperate datasheet AC-types see seperate datasheet E3F2 L-on / D-on selectable by wiring M12 connector or pre-wired. 1 Selection Guide Housing Material: Plastic Sensing method Sensing distance Connection method Order code PNP output NPN output *1 Through-beam Retro-reflective with 7m M.S.R.*2 Retro-reflective with M.S.R. *2 Diffuse-reflective Diffuse-reflective Diffuse reflective (background suppression) *1. *2. *3. *4. 0.1 to 4 m (adjustable)*3 0.1 to 2 m - - 2m - E3F2-7B4 2M E3F2-7C4 2M - - - E3F2-7B4-P1 E3F2-7C4-P1 - - 2m - E3F2-R4B4-E 2M E3F2-R4C4-E 2M - - - E3F2-R4B4-P1-E E3F2-R4C4-P1-E - - 2m - E3F2-R2RB41-E 2M E3F2-R2RC41-E 2M - - - E3F2-R2RB41-P1-E E3F2-R2RC41-P1-E *4 0.1 m (fixed, wide-beam) - - 2m - E3F2-DS10B4-N 2M E3F2-DS10C4-N 2M - - - E3F2-DS10B4-P1 E3F2-DS10C4-P1 0.3 m (adjustable) - - 2m - E3F2-DS30B4 2M E3F2-DS30C4 2M - - - E3F2-DS30B4-P1 E3F2-DS30C4-P1 1m (adjustable) - - 2m - E3F2-D1B4 2M E3F2-D1C4 2M - - - E3F2-D1B4-P1 E3F2-D1C4-P1 - - 2m - E3F2-DS30B41 2M E3F2-DS30C41 2M - - - E3F2-DS30B41-P1 E3F2-DS30C41-P1 - - 2m - E3F2-LS10B4 2M E3F2-LS10C4 2M - - - E3F2-LS10B4-P1 E3F2-LS10C4-P1 0.3 m (adjustable) 0.1 m (fixed) Pre-wired connectors are available on request. Please contact your OMRON representative. Order reflector seperately. Models with reflector included are also available. Please contact your OMRON representative. Measured with reflector E39-R1S Measured with reflector E39-R1 Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable (e.g. E3F2-R4B4-E 5M). For other cable length please contact your OMRON sales representative. Housing material: Metal (Nickel plated brass) Sensing method Sensing distance Connection method Order code PNP output NPN output *1 Through-beam Retro-reflective with M.S.R.*2 Retro-reflective with M.S.R.*2 Diffuse-reflective 7m 0.1 to 4 m (adjustable)*3 0.1 to 2 m*4 0.1 m (fixed, wide-beam) 0.3 m (adjustable) 1m (adjustable) Diffuse-reflective 2 0.3 m (adjustable) - - 2m - E3F2-7B4-M 2M E3F2-7C4-M 2M - - - E3F2-7B4-M1-M E3F2-7C4-M1-M - - 2m - E3F2-R4B4-M-E 2M E3F2-R4C4-M-E 2M - - - E3F2-R4B4-M1-M-E E3F2-R4C4-M1-M-E - - 2m - - - - - - 2m - - - - - 2m - - - - 2m - - - E3F2-R2RB41-M-E 2M E3F2-R2RC41-M-E 2M E3F2-R2RB41-M1-M-E E3F2-R2RC41-M1-M-E E3F2-DS10B4-M 2M E3F2-DS10C4-M 2M - E3F2-DS10B4-M1-M E3F2-DS10C4-M1-M - E3F2-DS30B4-M 2M E3F2-DS30C4-M 2M - E3F2-DS30B4-M1-M E3F2-DS30C4-M1-M - E3F2-D1B4-M 2M E3F2-D1C4-M 2M E3F2-D1B4-M1-M E3F2-D1C4-M1-M E3F2-DS30B41-M 2M E3F2-DS30C41-M 2M - - 2m - - - - E3F2-DS30B41-M1-M E3F2-DS30C41-M1-M Standard Photoelectric Sensors Sensing method Sensing distance Connection method Order code PNP output NPN output E3F2-LS10B4-M 2M E3F2-LS10C4-M 2M E3F2-LS10B4-M1-M E3F2-LS10C4-M1-M *1 Diffuse-reflective (background suppression) *1. *2. *3. *4. 0.1 m (fixed) - - 2m - - - - Pre-wired connectors are available on request. Please contact your OMRON representative. Order reflector separately. Models with reflector E39-R1S included are available. Please contact your OMRON representative. with reflector E39-R1S with reflector E39-R1 Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adapting the length of the cable (e.g. E3F2-R4B4-E 5M). For other cable length please contact your OMRON sales representative. Accessories (Order Separately) Name Sensing distance (typical)*1 Remark Order code Reflectors 3 m [100 mm] (axial types) 2 m [100 mm] (radial types) 60 x 40 mm E39-R1 4 m [100 mm] (axial types) 2 m [100 mm] (radial types) 60 x 40 mm E39-R1S 5 m [100 mm] (axial types) 2.5 m [100 mm] (radial types) 84 mm E39-R7 6 m [100 mm] (axial types) 3 m [100 mm] (radial types) 100 x 100 mm E39-R8 5 m [100 mm] (axial types) 2.5 m [100 mm] (radial types) 80 x 80 mm E39-R40 Tape Reflectors 0.7 m [150 mm] (axial types) 1.1 m [150 mm] (axial types) 1.4 m [150 mm] (axial types) 35 x 10 mm E39-RS1 35 x 40 mm E39-RS2 80 x 70 mm E39-RS3 Lens Cap E39-F31 Mounting Bracket *1. screw mount Y92E-B18 Values in parentheses indicate the minimum required distance between the sensor and reflector. For detailed information about Accessories, refer to the main chapter "Accessories" at the end of the document. Sensor I/O Connectors Cord Shape Cable type Standard Straight 2m L-shaped Vibration-proof robot cable Straight L-shaped E3F2 Order code Four-wire type XS2F-D421-D80-A 5m XS2F-D421-G80-A 2m XS2F-D422-D80-A 5m XS2F-D422-G80-A 2m XS2F-D421-D80-R 5m XS2F-D421-G80-R 2m XS2F-D422-D80-R 5m XS2F-D422-G80-R 3 Specifications Ratings Item E3F2-7@ E3F2-R4@-@ E3F2-DS10@ Sensing method Through-beam Retro-reflective with M.S.R. Diffuse-reflective E3F2-DS30@ E3F2-D1@4-@ Wide beam Potentiometer adjustment Power supply voltage 10 to 30 VDC Current consumption 50 mA max. 30 mA max. 25 mA max. 30 mA max. Sensing distance 7m 0.1 to 4 m (with E39-R1S) 0.1 m (5 x 5 cm white mat paper) 0.3 m (10 x 10 cm white mat paper) Standard object Opaque: 11 mm dia. min. Opaque: 56 mm dia. min. - Directional angle 3 to 20 - Differential travel (hysteresis) - 20% max. 1m (30 x 30 cm white mat paper) E3F2-LS10@4-@ Background suppression 0.1 m (10 x 10 cm white mat paper) 5% max Black/white error - Response time Operation and Reset: 2.5 ms max. 3% Control output Transistor (open collector), load current: 100 mA max. (residual voltage: 2 V max.) 1 ms max 100 ms max. 2.5 ms max. 1 ms max. Power reset time 50 ms Ambient illumination Incandescent lamp:3000 lx max. / Sunlight:10000 lx max. 50 ms 100 ms Ambient temperature Operating: -25 to 55 C / Storage: -30 to 70 C (with no icing or condensation) Ambient humidity Operating: 35% to 85% / Storage: 35% to 95% (with no condensation) Insulation resistance 20 M min. at 500 V DC between energized parts and case Dielectric strength 1000 VAC max., 50 / 60 Hz for 1 min between energized parts and case Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z) Shock resistance Destruction: 500 m/s2 each direction (X, Y, Z) Degree of protection*1 IEC 60529 IP67, IP69K after DIN 40050-9 Light source (wave length) Infrared LED (950 nm) Red LED (660 nm) Infrared LED (880 nm) Indicators Light incident / power indicator for light source (red) Light incident (red) / stability (green) Light incident / power indicator for light source (red) Sensitivity adjustment Fixed Adjustable Fixed Connection method 2 m, 5 m pre-wired cable (PVC, dia. 4 mm (18 / Operation mode Light-ON or Dark-ON selectable by wiring Red LED (660 nm) Light incident (red) / stability (green) Adjustable 0.12)*2) Output indicator (orange) / stability (green) Fixed or M12-connector Weight (approx.) Plastic pre-wired case (2 m) Metal case 120 g 60 g connector 40 g 20 g pre-wired (2 m) 180 g 90 g 120 g 50 g connector Circuit protection Output short-circuit and power supply reverse polarity Housing materials*3 Case: ABS (plastic models) or nickel brass (metal models); lens: PMMA *1. *2. *3. 4 The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water at 80C is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from high pressure water in appearance and functionality. For other cable materials (e.g. PUR) contact your OMRON sales representative. For stainless steel types refer to separate datasheet E3F2 SUS Standard Photoelectric Sensors Engineering Data (Typical) Operating Range (typical) Through-beam Models (axial) Retro-reflective Models (axial) Retro-reflective Models (radial) E3F2-7@4-@ E3F2-R4@4@-@ (polarizing) E3F2-R2R@41-@ (polarizing) and reflectors 250 200 typical sensing distances: E39-R1: 2.4 m E39-R7: 2.7 m E39-R8: 3.1 m 50 100 Distance Y (mm) Distance Y (mm) 150 100 Typical sensing distance E39-RS3 E39-R1S E39-R40 E39-R7 E39-R8 50 0 - 50 - 100 0 -50 - 150 - 200 Y Y Reflector - 250 0 1 2 3 4 5 6 7 -100 8 0 9 0.5 1 1.5 2 2.5 3 3.5 Diffuse-reflective Models (axial) Diffuse-reflective Models (axial) Diffuse-reflective Models (radial) E3F2-DS10@4-@ (wide-beam type) E3F2-DS30@4-@ E3F2-DS30@41-@ 40 4 Distance X (m) Distance X (m) 15 Reflector X X 40 Sensitivity adjusted to maximum Sensitivity adjusted to 400 mm 30 30 20 20 Sensitivity adjusted to 390 mm White paper (90% reflectivity) white paper (50 x 50 mm) 0 -5 10 white paper (100 x 100 mm) 0 -10 -20 Distance Y (mm) 5 Distance Y (mm) Distance Y (mm) 10 10 Sensing object: 100 x 100 mm 0 -10 -20 Sensing distance adjustable between 0 and 550 mm -10 Y Object -30 Y X Object -30 -15 20 40 60 80 100 120 140 Distance X (mm) Object X -40 0 Y X -40 0 100 200 300 400 500 600 Distance X (mm) 0 100 200 300 400 500 Distance X (mm) Diffuse-reflective Models (axial) E3F2-D1@4-@ 100 80 Distance Y (mm) 60 40 20 Sensing object: 300 x 300 mm 0 -20 -40 -60 Y -80 Object X -100 0 200 400 600 800 1000 1200 1400 1600 Distance X (mm) E3F2 5 Excess Gain Ratio vs. Distance (typical) Through-beam Models (axial) Retro-reflective Models (axial) Retro-reflective Models (radial) E3F2-7@4-@ E3F2-R4@4@-@ E3F2-R2R@41-@ (polarizing) and reflectors 100 10 100 Reflectors: E39-RS3 E39-R1S E39-R40 E39-R7 E39-R8 1 Excess gain 10 Excess Gain Excess gain 100 1 10 reflector E39-R1 1 reflector E39-R7 reflector E39-R8 0.1 0 2 4 6 8 10 0.1 0.1 12 0 2 4 6 Distance X (m) 8 0 10 1 2 3 4 Diffuse-reflective Models (axial) Diffuse-eflective Models (axial) Diffuse-reflective Models (radial) E3F2-DS10@4-@ (wide-beam type) E3F2-DS30@4-@ E3F2-DS30@41-@ 100 100 White paper (90% reflectivity) Grey paper (18% reflectivity) 10 Excess gain Excess gain Excess gain Sensing object: 100 x 100 mm Sensitivity adjusted to 390 mm 10 1 100 Sensitivity adjusted to maximum Sensing object: 100 x 100 mm Sensing object: 50 x 50 mm White paper (90% reflectivity) 1 10 White paper (90% reflectivity) 1 Grey paper (18% reflectivity) Grey paper (18% reflectivity) 0.1 0.1 0 20 40 60 80 100 120 5 Distance X (m) Distance X (m) 0.1 0 140 200 400 600 800 1000 Distance X (mm) Distance X (mm) 0 100 200 300 400 500 Distance X (mm) Diffuse-reflective Models (axial) E3F2-D1@4-@ Excess gain 100 10 1 0,1 0 0.5 1 1.5 2 Distance(m) 6 Standard Photoelectric Sensors Light spot vs sensing distance Incline (horizontal) Incline (vertical) Background suppression Models Background suppression Models Background suppression Models E3F2-LS@ E3F2-LS@ E3F2-LS@ 4 2 Sensing Distence movement (%) Sensing Distence movement (%) Spot diameter(mm) 20,00% 20,00% 6 10,00% 0,00% -10,00% 0 50 100 150 Distance(mm) 0,00% -10,00% -20,00% -20,00% 0 10,00% -40 -30 -20 -10 0 10 20 30 40 Incline Angle () -40 -30 -20 -10 0 10 20 30 40 Incline Angle () Object material vs sensing distance Background suppression Models Sensing distance (mm) E3F2-LS@ 120 100 80 60 40 20 0 White Veneer Card- Black Black SUS paper board paper rubber Mirror surface Material E3F2 7 Operation Output Circuits Structure of Sensor I/O Connector 1 2 3 4 Classification Wire color Connector Use pin No. Brown White Blue Black DC XS2F-D42#-D80-# XS2F-G42#-G80-# Brown Power supply (+V) White Mode selection Lon/Don Blue Power supply (0 V) Black Output PNP Output Model Output transistor Timing chart status Connection method Output circuit E3F2-@B4-@ (except for E3F2-LS10B4-@) - - Through-beam emitter - Brown 10 to 30 VDC 1 Power indicator (red) Main circuit Blue 3 0V Connector Pin Arrangement 1 2 4 3 ON when light is incident. (Light-ON) Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Operate Release Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Light indicator Red Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Connect the pink (Pin ) and blue (Pin ) cords. 10 to 30 VDC 1 ZD Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. Load 3 0V Pink Mode selection 2 Connector Pin Arrangement 1 * Only on models E3F2-R4B4-@ and E3F2-D1B4-@ ON when light is interrupted. (Dark-ON) Brown Stability indicator* Light indicator Red 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. Load 3 0V Pink Load (relay) Operate Release Connector Pin Arrangement 1 * Only on models E3F2-R4B4-@ and E3F2-D1B4-@ E3F2-LS10B4-@ ON when light is incident. (Light-ON) Incident Interrupted Output indicator (orange) ON OFF Output transistor ON OFF Load (relay) Operate Release Mode selection 2 Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Output indicator Orange 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 ZD Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. Load 3 0V Pink Mode selection 2 Connector Pin Arrangement 1 2 4 3 ON when light is interrupted. (Dark-ON) Incident Interrupted Output indicator (orange) ON OFF Output transistor ON OFF Connect the pink (Pin ) and blue (Pin ) cords. Output indicator Orange Brown Stability indicator* 10 to 30 VDC 1 Green Black 4 Main circuit ZD: VZ = 36 V Blue 100 mA max. 3 Load 0V Pink Load (relay) Operate Release 2 Mode selection Connector Pin Arrangement 1 2 4 3 Note: Terminal numbers for connector type. 8 Standard Photoelectric Sensors NPN Output Model Output transistor Timing chart status Connection method Output circuit E3F2-@C4-@ (except for E3F2-LS10C4-@) - - Through-beam emitter Brown 10 to 30 VDC 1 Power indicator (red) Main circuit Blue 3 0V Connector Pin Arrangement 1 2 4 3 ON when light is incident. (Light-ON) Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Operate Release Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Output indicator Red Brown Stability indicator* Green Incident Interrupted Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Connect the pink (Pin ) and blue (Pin ) cords. ON when light is incident. (Light-ON) Output indicator (red) ON OFF Output transistor ON OFF Load (relay) Operate Release Blue 3 0V Pink Mode selection 2 Connector Pin Arrangement Output indicator Red 1 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 Green 100 mA max. Black 4 Main circuit Load Blue 3 0V ZD: VZ = 36 V Pink Mode selection 2 Operate Release Incident Interrupted Load ZD: VZ = 36 V Connector Pin Arrangement 1 * Only on models E3F2-R4C4-@ and E3F2-D1C4-@ E3F2-LS10C4-@ 100 mA max. Black 4 Main circuit * Only on models E3F2-R4C4-@ and E3F2-D1C4-@ ON when light is interrupted. (Dark-ON) 10 to 30 VDC 1 Connect the pink (Pin ) and brown (Pin ) cords or open the pink cord (Pin ). Output indicator Orange 2 4 3 Brown Stability indicator* 10 to 30 VDC 1 Green 100 mA max. Black 4 Main circuit Load Blue 3 0V ZD: VZ = 36 V Pink Mode selection 2 Connector Pin Arrangement 1 2 4 3 ON when light is interrupted. (Dark-ON) Incident Interrupted Output indicator (orange) ON OFF Output transistor ON OFF Connect the pink (Pin ) and blue (Pin ) cords. Output indicator Orange Brown Stability indicator* 10 to 30 VDC 1 Green 100 mA max. Black 4 Main circuit Load Blue 3 0V ZD: VZ = 36 V Pink Load (relay) Operate Release 2 Mode selection Connector Pin Arrangement 1 2 4 3 Note: Terminal numbers for connector type. E3F2 9 Dimensions Note: All units are in millimeters unless otherwise indicated Plastic models, axial type Cable type Connector type Without potentiometer E3F2-7@-P1 E3F2-DS10@4-P1 E3F2-LS10@4-P1 5 5 Light indicator 4 M12x1 6g 24 optical area 24 22 6.2 22 optical area 4.7 dia 6.2 37 4 dia 42.3 16.4 dia 64.9 73 62 42.3 37 4.8 dia 16.6 dia E3F2-7@ E3F2-DS10@4-N E3F2-LS10@4 Light indicator 4 M18x1 6g M18x1 6g 8 8 With potentiometer E3F2-DS30@4-P1 E3F2-D1@4-P1 E3F2-R4@-P1 22 5 5 4 8 Sensitivity adjustor Light indicator optical area 24 6.2 24 4.7 dia 22 6.2 16.4 dia optical area M12x1 6g 73 62 49.3 42.3 37 4.8 dia 4 dia 64.9 49.3 42.3 37 16.6 dia E3F2-DS30@4 E3F2-D1@4 E3F2-R4@ Sensitivity adjustor 4 8 Light indicator M18x1 6g M18x1 6g 10 Standard Photoelectric Sensors Plastic models, radial type Cable type Connector type Without potentiometer E3F2-R2R@41-P1 5 5 Light indicator 6.9 4 24 22 optical area 22 4 dia 24 4.7 dia 13.2 optical area 16.4 dia 42.3 37 73 62 42.3 37 4.8 dia 13.2 64.9 M12x1 6g 16.6 dia E3F2-R2R@41 3.45 Light indicator 6.9 M18x1 6g 4 3.45 M18x1 6g 8 8 With potentiometer 4.7 dia 5 8 Sensitivity adjustor Light indicator 24 22 3.45 4 6.9 optical area 13.2 24 13.2 optical area M12x1 6g 73 62 49.3 42.3 37 22 4 dia 37 4.8 dia 16.4 dia 64.9 49.3 42.3 E3F2-DS30@41-P1 16.6 dia E3F2-DS30@41 5 Sensitivity adjustor 6.9 4 8 3.45 Light indicator M18x1 6g M18x1 6g E3F2 11 Metal Models, axial type Cable type Connector type Without potentiometer E3F2-7@-M1-M E3F2-DS10@4-M1-M E3F2-LS10@4-M1-M 76 4 4.8 dia 42.3 37 optical area 24 6.2 27.7 24 4 Light indicator 6.2 optical area M12x1 6g 65.5 27.7 4 dia 4.8 dia 16.4 dia 64.9 42.3 37 16.4 dia E3F2-7@-M E3F2-DS10@4-M E3F2-LS10@4-M Light indicator M18x1 6g M18x1 6g With potentiometer E3F2-DS30@4-M E3F2-R4@4-M E3F2-D1@4-M 76 65.5 37 4 Sensitivity adjustor Light indicator M18x1 6g 27.7 optical area 4 24 6.2 24 4.8 dia 16.4 dia 49.3 42.3 M12x1 6g optical area 27.7 6.2 16.4 dia 4.8 dia 4 dia 64.9 49.3 42.3 37 E3F2-DS30@4-M1-M E3F2-R4@4-M1-M E3F2-D1@4-M1-M Sensitivity adjustor Light indicator M18x1 6g 12 Standard Photoelectric Sensors Metal Models, radial type Cable type Connector type Without potentiometer 76 65.5 42.3 37 4.8 dia 6.9 4 13.2 optical area 24 27.7 16.4 dia 24 13.2 optical area 27.7 42.3 37 4.8 dia 4 dia 16.4 dia 64.9 E3F2-R2R@41-M1 M12x1.6g E3F2-R2R@41-M 3.45 Light indicator M18x1 6g 6.9 4 3.45 Light indicator M18x1.6g With potentiometer E3F2-DS30@41-M 76 65.5 6.9 E3F2 4 Sensitivity adjustor Light indicator M18x1 6g optical area 27.7 24 13.2 16.4 dia 37 27.7 24 4.8 dia M12x1 6g 49.3 42.3 optical area 13.2 4.8 dia 4 dia 16.4 dia 64.9 49.3 42.3 37 E3F2-DS30@41-M1-M 3.45 6.9 4 Sensitivity adjustor 3.45 Light indicator M18x1 6g 13 Accessories (Order Separately) Reflector E39-R1 E39-R1S E39-R7 Two, 3.5 dia. 7.4 40.3 34 84 7.5 7 4.5 59.9 52 8 Material, reflective surface: acrylic Rear surface: ABS 2.7 1.6 E39-R8 E39-R40 9 8.7 100 84.5 77 92 92 77 100 for M3 for 84.5 for M3 Tape relectors E39-RS3 E39-RS1 35 0.6 0.7 10 80 Reflecting surface 4 x R1 70 Adhesive tape E39-RS2 40 0.7 35 4-R1 Adhesive tape side Reflecting surface 4 x R1 Adhesive tape Installation Mounting Bracket Y92E-B18 Lens Cap E39-F31 Glass plate Metal rim E3F2 Gasket 4 max. Note: Hexagon bolt: M5 x 32 Material: plastic 20 dia. 14 Standard Photoelectric Sensors Safety precautions Precautions for Correct Use ! Warning This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. ! Caution Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explostion may result. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0.39 to 0.49 N*m for M12 connectors. Load Do not use a load that exceeds the rated load. Rotation Torque for Sensitivity Adjustment Adjust with a torque of 0.05 N*m or less. Environements with Cleaners and Disinfectants (e.g., Food Processing Lines) Do not use the Sensor in environments subject to cleaners and disifectants. They may reduce the degree of protection. Modifications Do not attempt to disassemble, repair, or modify the Sensor. Outdoor Use Do not use the Sensor in locations subject to direct sunlight. Cleaning Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded. Do not use the Sensor in any atmosphere or environment that exceeds the ratings. Do not install the Sensor in the following locations. (1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity (3) Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock Connecting and Mounting (1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0.3 mm2 and less than 100 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. (6)Mount the Sensor using a bracket (sold separately). Do not exceed a torque of 2.0 Nm when tightening mounting nuts for plastic models or 20.0 Nm when tightening mounting nuts for metal models (7) Be sure to turn OFF the power supply before inserting or removing the connector. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Power Supply Reset Time The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Turning OFF the Power Supply Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. Load Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn OFF, so check the wiring before turning ON the power supply again. The short-circuit protection circuit will be reset. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. Surface Temperature Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. E3F2 15 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ("Omron"). Omron objects to any terms or conditions proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron's payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in "break down" situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- 14. 15. 16. 17. 18. ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron247.com or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to "forbidden" or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, "including" means "including without limitation"; and "Omron Companies" (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 2. 3. 4. 5. ADDRESS THE RISKS, AND THAT THE OMRON'S PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Cat. No. E58E-EN-01 07/08 Note: Specifications are subject to change. (c) 2010 Omron Electronics LLC