May 2005 1 M9999-051305
KS8995XA Micrel, Inc.
KS8995XA
Integrated 5-Port 10/100 QoS Switch
Rev. 2.3
General Description
The KS8995XA is a highly integrated Layer-2 quality of
service (QoS) switch with optimized bill of materials (BOM)
cost for low port count, cost-sensitive 10/100Mbps switch
systems. It also provides an extensive feature set including
three different QoS priority schemes, a dual MII interface for
BOM cost reduction, rate limiting to offload CPU tasks,
software and hardware power-down, a MDC/MDIO control
interface and port mirroring/monitoring to effectively address
both current and emerging Fast Ethernet applications.
The KS8995XA contains five 10/100 transceivers with pat-
ented mixed-signal low-power technology, five media access
control (MAC) units, a high-speed non-blocking switch fabric,
a dedicated address lookup engine, and an on-chip frame
buffer memory.
All PHY units support 10BASE-T and 100BASE-TX. In addi-
tion, two of the PHY units support 100BaseFX (Ports 4 and 5).
Features
•Integrated switch with five MACs and five Fast Ethernet
transceivers fully compliant to IEEE 802.3u standard
Shared memory based switch fabric with fully non-
blocking configuration
10BASE-T, 100BASE-TX and 100BASE-FX modes
(FX in Ports 4 and 5)
Dual MII configuration: MII-Switch (MAC or PHY
mode MII) and MII-P5 (PHY mode MII)
VLAN ID tag/untag options, per-port basis
Enable/disable option for huge frame size up to
1916 bytes per frame
•Broadcast storm protection with percent control
global and per-port basis
Optimization for fiber-to-copper media conversion
Full-chip hardware power-down support (register
configuration not saved)
Per-port-based software power-save on PHY
(idle link detection, register configuration preserved)
QoS/CoS packets prioritization supports: per port,
802.1p and DiffServ-based
Micrel, Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel + 1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
Functional Diagram
1K Look-Up
Engine
Queue
Mgmnt
10/100
MAC 1
Buffer
Mgmnt
Frame
Buffers
FIFO, Flow Control, VLAN Tagging, Priority
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
SNI
10/100
T/Tx 1
10/100
T/Tx 2
10/100
T/Tx 3
10/100
T/Tx/Fx 4
10/100
T/Tx/Fx 5
EEPROM
I/F
LED I/F
Auto
MDI/MDI-X
MII-SW or SNI
LED0[5:1]
LED1[5:1]
LED2[5:1] Control
Registers
MII-P5
MDC, MDI/O
KS8995XA
Auto
MDI/MDI-X
Auto
MDI/MDI-X
Auto
MDI/MDI-X
Auto
MDI/MDI-X
KS8995XA Micrel, Inc.
M9999-051305 2May 2005
Features (continued)
802.1p/q tag insertion or removal on a per-port basis
(egress)
Port-based VLAN support
MDC and MDI/O interface support to access the MII
PHY control registers (not all control registers)
•MII local loopback support
On-chip 64Kbyte memory for frame buffering (not
shared with 1K unicast address table)
•1.4Gbps high performance memory bandwidth
•Wire-speed reception and transmission
•Integrated look-up engine with dedicated 1K unicast
MAC addresses
Automatic address learning, address aging and address
migration
Full-duplex IEEE 802.3x and half-duplex back pressure
flow control
Comprehensive LED support
•7-wire SNI support for legacy MAC interface
Automatic MDI/MDI-X crossover for plug-and-play
•Disable automatic MDI/MDI-X option
Low power
Core: 1.8V
I/O: 2.5 or 3.3V
•0.18µm CMOS technology
Commercial temperature range: 0°C to +70°C
Available in 128-pin PQFP package
Applications
•Broadband gateway/firewall/VPN
•Integrated DSL or cable modem multi-port router
•Wireless LAN access point plus gateway
Home networking expansion
•Standalone 10/100 switch
Hotel/campus/MxU gateway
Enterprise VoIP gateway/phone
FTTx customer premise equipment
Media converter
Ordering Information
Part Number Temp. Range Package Lead Finish
KS8995XA 0°C to +70°C128-Pin PQFP Standard
KSZ8995XA 0°C to +70°C128-Pin PQFP Pb-Free
May 2005 3 M9999-051305
KS8995XA Micrel, Inc.
Revision History
Revision Date Summary of Changes
2.0 10/15/03 Created.
2.1 4/1/04 Editorial changes on TTL input and output electrical characteristics.
2.2 1/19/05 Insert recommeneded reset circuit.
2.3 4/13/05 Switched pins names for pins 7 & 8 on page 16.
Changed VDDIO to 3.3V.
Changed Jitter to 16 ns Max.
KS8995XA Micrel, Inc.
M9999-051305 4May 2005
Table of Contents
System Level Applications .............................................................................................................................................................. 6
Pin Description (by Number) ........................................................................................................................................................... 8
Pin Description (by Name) ............................................................................................................................................................ 13
Pin Configuration ........................................................................................................................................................................... 18
Introduction ............................................................................................................................................................................ 19
Functional Overview: Physical Layer Transceiver ..................................................................................................................... 19
100BASE-TX Transmit ............................................................................................................................................................ 19
100BASE-TX Receive ............................................................................................................................................................. 19
PLL Clock Synthesizer ............................................................................................................................................................ 19
Scrambler/De-scrambler (100BASE-TX only) ......................................................................................................................... 19
100BaseFX Operation ............................................................................................................................................................. 19
100BaseFX Signal Detection ................................................................................................................................................... 20
100BaseFX Far End Fault ....................................................................................................................................................... 20
10BASE-T Transmit ................................................................................................................................................................. 20
10BASE-T Receive .................................................................................................................................................................. 20
Power Management ................................................................................................................................................................ 20
MDI/MDI-X Auto Crossover ..................................................................................................................................................... 20
Auto-Negotiation ...................................................................................................................................................................... 20
Functional Overview: Switch Core ............................................................................................................................................... 21
Address Look Up ..................................................................................................................................................................... 21
Learning ............................................................................................................................................................................ 21
Migration ............................................................................................................................................................................ 21
Aging ............................................................................................................................................................................ 21
Switching Engine ..................................................................................................................................................................... 21
MAC (Media Access Controller) Operation ............................................................................................................................. 22
Inter-Packet Gap ............................................................................................................................................................. 22
Backoff Algorithm ............................................................................................................................................................ 22
Late Collision .................................................................................................................................................................. 22
Illegal Frame ................................................................................................................................................................... 22
Flow Control .................................................................................................................................................................... 22
Half-Duplex Back Pressure ............................................................................................................................................. 22
Broadcast Storm Protection ............................................................................................................................................ 23
MII Interface Operation .................................................................................................................................................................. 23
SNI Interface Operation ................................................................................................................................................................. 25
Advanced Functionality ................................................................................................................................................................. 25
QoS Support ............................................................................................................................................................................ 25
Rate Limit Support ................................................................................................................................................................... 27
Configuration Interface ............................................................................................................................................................ 28
I2C Master Serial Bus Configuration ............................................................................................................................... 28
MII Management Interface (MIIM) .................................................................................................................................................. 28
Register Map ............................................................................................................................................................................ 29
Global Registers ...................................................................................................................................................................... 29
Register 0 (0x00): Chip ID0 ............................................................................................................................................ 29
Register 1 (0x01): Chip ID1/Start Switch ....................................................................................................................... 29
Register 2 (0x02): Global Control 0 ................................................................................................................................ 29
Register 3 (0x03): Global Control 1 ................................................................................................................................ 30
Register 4 (0x04): Global Control 2 ................................................................................................................................ 31
Register 5 (0x05): Global Control 3 ................................................................................................................................ 31
Register 6 (0x06): Global Control 4 ................................................................................................................................ 32
Register 7 (0x07): Global Control 5 ................................................................................................................................ 32
May 2005 5 M9999-051305
KS8995XA Micrel, Inc.
Register 8 (0x08): Global Control 6 ................................................................................................................................ 32
Register 9 (0x09): Global Control 7 ................................................................................................................................ 32
Register 10 (0x0A): Global Control 8 ............................................................................................................................. 32
Register 11 (0x0B): Global Control 9 ............................................................................................................................. 33
Port Registers .......................................................................................................................................................................... 33
Register 16 (0x10): Port 1 Control 0 .............................................................................................................................. 33
Register 17 (0x11): Port 1 Control 1 .............................................................................................................................. 34
Register 18 (0x12): Port 1 Control 2 .............................................................................................................................. 34
Register 19 (0x13): Port 1 Control 3 .............................................................................................................................. 35
Register 20 (0x14): Port 1 Control 4 .............................................................................................................................. 35
Register 21 (0x15): Port 1 Control 5 .............................................................................................................................. 35
Register 22 (0x16): Port 1 Control 6 .............................................................................................................................. 35
Register 23 (0x17): Port 1 Control 7 .............................................................................................................................. 36
Register 24 (0x18): Port 1 Control 8 .............................................................................................................................. 36
Register 25 (0x19): Port 1 Control 9 .............................................................................................................................. 36
Register 26 (0x1A): Port 1 Control 10 ............................................................................................................................ 36
Register 27 (0x1B): Port 1 Control 11 ............................................................................................................................ 37
Register 28 (0x1C): Port 1 Control 12 ............................................................................................................................ 37
Register 29 (0x1D): Port 1 Control 13 ............................................................................................................................ 38
Register 30 (0x1E): Port 1 Status 0 ............................................................................................................................... 39
Register 31 (0x1F): Port 1 Control 14 ............................................................................................................................ 39
Advanced Control Registers .................................................................................................................................................... 39
Register 96 (0x60): TOS Priority Control Register 0 ...................................................................................................... 39
Register 97 (0x61): TOS Priority Control Register 1 ...................................................................................................... 40
Register 98 (0x62): TOS Priority Control Register 2 ...................................................................................................... 40
Register 99 (0x63): TOS Priority Control Register 3 ...................................................................................................... 40
Register 100 (0x64): TOS Priority Control Register 4 .................................................................................................... 40
Register 101 (0x65): TOS Priority Control Register 5 .................................................................................................... 40
Register 102 (0x66): TOS Priority Control Register 6 .................................................................................................... 40
Register 103 (0x67): TOS Priority Control Register 7 .................................................................................................... 40
Register 104 (0x68): MAC Address Register 0 .............................................................................................................. 40
Register 105 (0x69): MAC Address Register 1 .............................................................................................................. 40
Register 106 (0x6A): MAC Address Register 2 .............................................................................................................. 40
Register 107 (0x6B): MAC Address Register 3 .............................................................................................................. 40
Register 108 (0x6C): MAC Address Register 4 ............................................................................................................. 40
Register 109 (0X6D): MAC Address Register 5 ............................................................................................................. 40
MIIM Registers ........................................................................................................................................................................ 40
Register 0: MII Control ................................................................................................................................................... 40
Register 1: MII Status .................................................................................................................................................... 41
Register 2: PHYID HIGH ................................................................................................................................................ 41
Register 3: PHYID LOW ................................................................................................................................................ 41
Register 4: Advertisement Ability ................................................................................................................................... 41
Register 5: Link Partner Ability ....................................................................................................................................... 42
Absolute Maximum Ratings .......................................................................................................................................................... 43
Operating Ratings .......................................................................................................................................................................... 43
Electrical Characteristics .............................................................................................................................................................. 43
Timing Diagrams ............................................................................................................................................................................ 45
Selection of Isolation Transformers ............................................................................................................................................. 50
Package Information ...................................................................................................................................................................... 51
KS8995XA Micrel, Inc.
M9999-051305 6May 2005
System Level Applications
rnal W
Ethernet
MAC
CPU
Switch Controller
On-Chip Frame Buffers
MII-SW
10/100
PHY 5
4-port
LAN
MII-P5
1-port
WAN I/F
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
KS8995XA
Exte AN port PHY not required.
EEPROM
I/F EEPROM
Ethernet
MAC
Figure 1. Broadband Gateway
Ethernet
MAC
Switch Controller
On-Chip Frame Buffers
MII-SW
10/100
PHY 5
4-port
LAN
MII-P5
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
KS8995XA
EEPROM
I/F EEPROM
CPU
WAN PHY & AFE
(XDSL, CM...)
Figure 2. Integrated Broadband Router
May 2005 7 M9999-051305
KS8995XA Micrel, Inc.
Switch Controller
On-Chip Frame Buffers
10/100
PHY 5
5-port
LAN
10/100
MAC 1
10/100
MAC 2
10/100
MAC 3
10/100
MAC 4
10/100
MAC 5
10/100
PHY 1
10/100
PHY 2
10/100
PHY 3
10/100
PHY 4
KS8995XA
EEPROM
I/F
EEPROM
Figure 3. Standalone Switch
KS8995XA Micrel, Inc.
M9999-051305 8May 2005
Pin Description (by Number)
Pin Number Pin Name Type(1) Port Pin Function(2)
1MDI-XDIS I 1-5 Disable auto MDI/MDI-X.
PD (default) = normal operation.
PU = disable auto MDI/MDI-X on all ports.
2GNDA Gnd Analog ground.
3VDDAR P 1.8V analog VDD.
4RXP1 I 1 Physical receive signal + (differential).
5RXM1 I 1 Physical receive signal – (differential).
6GNDA Gnd Analog ground.
7TXP1 O 1 Physical transmit signal + (differential).
8TXM1 O 1 Physical transmit signal – (differential).
9VDDAT P 2.5V or 3.3V analog VDD.
10 RXP2 I 2 Physical receive signal + (differential).
11 RXM2 I 2 Physical receive signal – (differential).
12 GNDA Gnd Analog ground.
13 TXP2 O 2 Physical transmit signal + (differential).
14 TXM2 O 2 Physical transmit signal – (differential).
15 VDDAR P 1.8V analog VDD.
16 GNDA Gnd Analog ground.
17 ISET Set physical transmit output current. Pull-down with a 3.01k 1%
resistor.
18 VDDAT P 2.5V or 3.3V analog VDD.
19 RXP3 I 3 Physical receive signal + (differential).
20 RXM3 I 3 Physical receive signal - (differential).
21 GNDA Gnd Analog ground.
22 TXP3 O 3 Physical transmit signal + (differential).
23 TXM3 O 3 Physical transmit signal – (differential).
24 VDDAT P 2.5V or 3.3V analog VDD.
25 RXP4 I 4 Physical receive signal + (differential).
26 RXM4 I 4 Physical receive signal - (differential).
27 GNDA Gnd Analog ground.
28 TXP4 O 4 Physical transmit signal + (differential).
29 TXM4 O 4 Physical transmit signal – (differential).
30 GNDA Gnd Analog ground.
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. PU = Strap pin pull-up.
PD = Strap pull-down.
Otri = Output tristated.
May 2005 9 M9999-051305
KS8995XA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function(2)
31 VDDAR P 1.8V analog VDD.
32 RXP5 I 5 Physical receive signal + (differential).
33 RXM5 I 5 Physical receive signal – (differential).
34 GNDA Gnd Analog ground.
35 TXP5 O 5 Physical transmit signal + (differential).
36 TXM5 O 5 Physical transmit signal – (differential).
37 VDDAT P 2.5V or 3.3V analog VDD.
38 FXSD5 I 5 Fiber signal detect/factory test pin.
39 FXSD4 I 4 Fiber signal detect/factory test pin.
40 GNDA Gnd Analog ground.
41 VDDAR P 1.8V analog VDD.
42 GNDA Gnd Analog ground.
43 VDDAR P 1.8V analog VDD.
44 GNDA Gnd Analog ground.
45 NC / MUX1 I No connect. Factory test pin.
46 NC / MUX2 I No connect. Factory test pin.
47 PWRDN_N Ipu Full-chip power down. Active low.
48 RESERVE/NC Reserved pin. No connect.
49 GNDD Gnd Digital ground.
50 VDDC P 1.8V digital core VDD.
51 PMTXEN Ipd 5 PHY[5] MII transmit enable.
52 PMTXD3 Ipd 5 PHY[5] MII transmit bit 3.
53 PMTXD2 Ipd 5 PHY[5] MII transmit bit 2.
54 PMTXD1 Ipd 5 PHY[5] MII transmit bit 1.
55 PMTXD0 Ipd 5 PHY[5] MII transmit bit 0.
56 PMTXER Ipd 5 PHY[5] MII transmit error.
57 PMTXC O 5 PHY[5] MII transmit clock. PHY mode MII.
58 GNDD Gnd Digital ground.
59 VDDIO P 3.3V digital VDD for digital I/O circuitry.
60 PMRXC O 5 PHY[5] MII receive clock. PHY mode MII.
61 PMRXDV Ipd/O 5 PHY[5] MII receive data valid.
62 PMRXD3 Ipd/O 5 PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow
control; PU = disable flow control.
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. PU = Strap pin pull-up.
PD = Strap pull-down.
Otri = Output tristated.
KS8995XA Micrel, Inc.
M9999-051305 10 May 2005
Pin Number Pin Name Type(1) Port Pin Function(2)
63 PMRXD2 Ipd/O 5 PHY[5] MII receive bit 2. Strap option: PD (default) = disable back
pressure; PU = enable back pressure.
64 PMRXD1 Ipd/O 5 PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive
collision packets; PU = does not drop excessive collision packets.
65 PMRXD0 Ipd/O 5 PHY[5] MII receive bit 0. Strap option: PD (default) = disable
aggressive back-off algorithm in half-duplex mode; PU = enable for
performance enhancement.
66 PMRXER Ipd/O 5 PHY[5] MII receive error. Strap option: PD (default) = packet size
1518/1522 bytes; PU = 1536 bytes.
67 PCRS Ipd/O 5 PHY[5] MII carrier sense/force duplex mode. See “Register 28.”
68 PCOL Ipd/O 5 PHY[5] MII collision detect/force flow control. See “Register 18.”
69 SMTXEN Ipd Switch MII transmit enable.
70 SMTXD3 Ipd Switch MII transmit bit 3.
71 SMTXD2 Ipd Switch MII transmit bit 2.
72 SMTXD1 Ipd Switch MII transmit bit 1.
73 SMTXD0 Ipd Switch MII transmit bit 0.
74 SMTXER Ipd Switch MII transmit error.
75 SMTXC I/O Switch MII transmit clock. PHY or MAC mode MII.
76 GNDD Gnd Digital ground.
77 VDDIO P 3.3V digital VDD for digital I/O circuitry.
78 SMRXC I/O Switch MII receive clock. PHY or MAC mode MII.
79 SMRXDV Ipd/O Switch MII receive data valid.
80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = Disable Switch MII
full-duplex flow control; PU = Enable Switch MII full-duplex flow control.
81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = Switch MII in
full-duplex mode; PU = Switch MII in half-duplex mode.
82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = Switch MII in
100Mbps mode; PU = Switch MII in 10Mbps mode.
83 SMRXD0 Ipd/O Switch MII receive bit 0; Strap option: see “Register 11[1].”
84 SCOL Ipd/O Switch MII collision detect.
85 SCRS Ipd/O Switch mode carrier sense.
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. PU = Strap pin pull-up.
PD = Strap pull-down.
Otri = Output tristated.
May 2005 11 M9999-051305
KS8995XA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function(2)
86 SCONF1 Ipd Dual MII configuration pin.
Pin# (91, 86, 87): Switch MII PHY [5] MII
000 Disable, Otri Disable, Otri
001 PHY Mode MII Disable, Otri
010 MAC Mode MII Disable, Otri
011 PHY Mode SNI Disable, Otri
100 Disable Disable
101 PHY Mode MII PHY Mode MII
110 MAC Mode MII PHY Mode MII
111 PHY Mode SNI PHY Mode MII
87 SCONF0 Ipd Dual MII configuration pin.
88 GNDD Gnd Digital ground.
89 VDDC P 1.8V digital core VDD.
90 LED5-2 Ipu/O 5 LED indicator 2. Aging setup. See “Aging” section.
91 LED5-1 Ipu/O 5 LED indicator 1. Strap option: PU (default): enable PHY MII I/F.
PD: tristate all PHY MII output. See “Pin# 86 SCONF1.”
92 LED5-0 Ipu/O 5 LED indicator 0.
93 LED4-2 Ipu/O 4 LED indicator 2.
94 LED4-1 Ipu/O 4 LED indicator 1.
95 LED4-0 Ipu/O 4 LED indicator 0.
96 LED3-2 Ipu/O 3 LED indicator 2.
97 LED3-1 Ipu/O 3 LED indicator 1.
98 LED3-0 Ipu/O 3 LED indicator 0.
99 GNDD Gnd Digital ground.
100 VDDIO P 3.3V digital VDD for digital I/O.
101 LED2-2 Ipu/O 2 LED indicator 2.
102 LED2-1 Ipu/O 2 LED indicator 1.
103 LED2-0 Ipu/O 2 LED indicator 0.
104 LED1-2 Ipu/O 1 LED indicator 2.
105 LED1-1 Ipu/O 1 LED indicator 1.
106 LED1-0 Ipu/O 1 LED indicator 0.
107 MDC Ipu All Switch or PHY[5] MII management data clock.
108 MDIO Ipu/O All Switch or PHY[5] MII management data I/O.
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. PU = Strap pin pull-up.
PD = Strap pull-down.
Otri = Output tristated.
KS8995XA Micrel, Inc.
M9999-051305 12 May 2005
Pin Number Pin Name Type(1) Port Pin Function
109 Reserved All No connect.
110 SCL I/O All Output clock at 81kHz in I2C master mode.
111 SDA I/O All Serial data input/output in I2C master mode.
112 Reserved All No connect
113 PS1 Ipd No connect or pull-down.
114 PS0 Ipd No connect or pull-down.
115 RST_N Ipu Reset the KS8995XA. Active low.
116 GNDD Gnd Digital ground.
117 VDDC P 1.8V digital core VDD.
118 TESTEN Ipd Factory test pin.
119 SCANEN Ipd Factory test pin.
120 NC NC No connection.
121 X1 I 25MHz crystal clock connection/or 3.3V tolerant oscillator input.
Oscillator should be ±100ppm.
122 X2 O 25MHz crystal clock connection.
123 VDDAP P 1.8V analog VDD for PLL.
124 GNDA Gnd Analog ground.
125 VDDAR P 1.8V analog VDD.
126 GNDA Gnd Analog ground.
127 GNDA Gnd Analog ground.
128 TEST2 Factory test pin.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
NC = No connect.
May 2005 13 M9999-051305
KS8995XA Micrel, Inc.
Pin Description (by Name)
Pin Number Pin Name Type(1) Port Pin Function
39 FXSD4 I 4 Fiber signal detect/factory test pin.
38 FXSD5 I 5 Fiber signal detect/factory test pin.
2GNDA Gnd Analog ground.
6GNDA Gnd Analog ground.
12 GNDA Gnd Analog ground.
16 GNDA Gnd Analog ground.
21 GNDA Gnd Analog ground.
27 GNDA Gnd Analog ground.
30 GNDA Gnd Analog ground.
34 GNDA Gnd Analog ground.
40 GNDA Gnd Analog ground.
42 GNDA Gnd Analog ground.
44 GNDA Gnd Analog ground.
120 NC NC No connection.
124 GNDA Gnd Analog ground.
126 GNDA Gnd Analog ground.
127 GNDA Gnd Analog ground.
49 GNDD Gnd Digital ground.
58 GNDD Gnd Digital ground.
76 GNDD Gnd Digital ground.
88 GNDD Gnd Digital ground.
99 GNDD Gnd Digital ground.
116 GNDD Gnd Digital ground.
17 ISET Set physical transmit output current. Pull down with a 3.01k 1%
resistor.
106 LED1-0 Ipu/O 1 LED indicator 0.
105 LED1-1 Ipu/O 1 LED indicator 1.
104 LED1-2 Ipu/O 1 LED indicator 2.
103 LED2-0 Ipu/O 2 LED indicator 0.
102 LED2-1 Ipu/O 2 LED indicator 1.
101 LED2-2 Ipu/O 2 LED indicator 2.
98 LED3-0 Ipu/O 3 LED indicator 0.
97 LED3-1 Ipu/O 3 LED indicator 1.
Note:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
NC = No connect.
KS8995XA Micrel, Inc.
M9999-051305 14 May 2005
Pin Number Pin Name Type(1) Port Pin Function(2)
96 LED3-2 Ipu/O 3 LED indicator 2.
95 LED4-0 Ipu/O 4 LED indicator 0.
94 LED4-1 Ipu/O 4 LED indicator 1.
93 LED4-2 Ipu/O 4 LED indicator 2.
92 LED5-0 Ipu/O 5 LED indicator 0.
91 LED5-1 Ipu/O 5 LED indicator 1. Strap option: PU (default): enable PHY MII I/F
Pd: tristate all PHY MII output. See “Pin# 86 SCONF1.”
90 LED5-2 Ipu/O 5 LED indicator 2. Aging setup. See “Aging” section.
107 MDC Ipu All Switch or PHY[5] MII management data clock.
108 MDIO Ipu/O All Switch or PHY[5] MII management data I/O.
45 NC / MUX1 I No connect. Factory test pin.
46 NC / MUX2 I No connect. Factory test pin.
68 PCOL Ipd/O 5 PHY[5] MII collision detect/ Force flow control. See “Register 18.”
67 PCRS Ipd/O 5 PHY[5] MII carrier sense/Force duplex mode. See “Register 28.”
60 PMRXC O 5 PHY[5] MII receive clock. PHY mode MII.
65 PMRXD0 Ipd/O 5 PHY[5] MII receive bit 0. Strap option: PD (default) = disable
aggressive back-off algorithm in half-duplex mode; PU = enable for
performance enhancement.
64 PMRXD1 Ipd/O 5 PHY[5] MII receive bit 1. Strap option: PD (default) = drop excessive
collision packets; PU = does not drop excessive collision packets.
63 PMRXD2 Ipd/O 5 PHY[5] MII receive bit 2. Strap option: PD (default) = disable back
pressure; PU = enable back pressure.
62 PMRXD3 Ipd/O 5 PHY[5] MII receive bit 3. Strap option: PD (default) = enable flow
control; PU = disable flow control.
61 PMRXDV Ipd/O 5 PHY[5] MII receive data valid.
66 PMRXER Ipd/O 5 PHY[5] MII receive error. Strap option: PD (default) = packet size 1518/
1522 bytes; PU = 1536 bytes.
57 PMTXC O 5 PHY[5] MII transmit clock. PHY mode MII.
55 PMTXD0 Ipd 5 PHY[5] MII transmit bit 0.
54 PMTXD1 Ipd 5 PHY[5] MII transmit bit 1.
53 PMTXD2 Ipd 5 PHY[5] MII transmit bit 2.
52 PMTXD3 Ipd 5 PHY[5] MII transmit bit 3.
51 PMTXEN Ipd 5 PHY[5] MII transmit enable.
56 PMTXER Ipd 5 PHY[5] MII transmit error.
114 PS0 Ipd No connect or pull down.
113 PS1 Ipd No connect or pull down.
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. PU = Strap pin pull-up.
PD = Strap pull-down.
May 2005 15 M9999-051305
KS8995XA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function(2)
47 PWRDN_N Ipu Full-chip power down. Active low.
48 RESERVE/NC Reserved pin. No connect.
109 Reserved All No connect.
112 Reserved All No connect.
115 RST_N Ipu Reset the KS8995X. Active low.
5RXM1 I 1 Physical receive signal - (differential).
11 RXM2 I 2 Physical receive signal - (differential).
20 RXM3 I 3 Physical receive signal - (differential).
26 RXM4 I 4 Physical receive signal - (differential).
33 RXM5 I 5 Physical receive signal - (differential).
4RXP1 I 1 Physical receive signal + (differential).
10 RXP2 I 2 Physical receive signal + (differential).
19 RXP3 I 3 Physical receive signal + (differential).
25 RXP4 I 4 Physical receive signal + (differential).
32 RXP5 I 5 Physical receive signal + (differential).
119 SCANEN Ipd Factory test pin.
110 SCL I/O All Output clock at 81kHz in I2C master mode. See “Pin# 113.”
84 SCOL Ipd/O Switch MII collision detect.
87 SCONF0 Ipd Dual MII configuration pin.
86 SCONF1 Ipd Dual MII configuration pin.
Pin# (91, 86, 87): Switch MII PHY [5] MII
000 Disable, Otri Disable, Otri
001 PHY Mode MII Disable, Otri
010 MAC Mode MII Disable, Otri
011 PHY Mode SNI Disable, Otri
100 Disable Disable
101 PHY Mode MII PHY Mode MII
110 MAC Mode MII PHY Mode MII
111 PHY Mode SNI PHY Mode MII
85 SCRS Ipd/O Switch MII carrier sense.
111 SDA I /O All Serial data input/output in I2C master mode. See “Pin# 113.”
78 SMRXC I/O Switch MII receive clock. PHY or MAC mode MII.
83 SMRXD0 Ipd/O Switch MII receive bit 0; strap option: see “Register 11[1].”
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. Otri = Output tristated.
KS8995XA Micrel, Inc.
M9999-051305 16 May 2005
Pin Number Pin Name Type(1) Port Pin Function(2)
82 SMRXD1 Ipd/O Switch MII receive bit 1. Strap option: PD (default) = Switch MII in
100Mbps mode; PU = Switch MII in 10Mbps mode.
81 SMRXD2 Ipd/O Switch MII receive bit 2. Strap option: PD (default) = Switch MII in full-
duplex mode; PU = Switch MII in half-duplex mode.
80 SMRXD3 Ipd/O Switch MII receive bit 3. Strap option: PD (default) = Disable Switch MII
full-duplex flow control; PU = Enable Switch MII full-duplex flow control.
79 SMRXDV Ipd/O Switch MII receive data valid.
75 SMTXC I/O Switch MII transmit clock. PHY or MAC mode MII.
73 SMTXD0 Ipd Switch MII transmit bit 0.
72 SMTXD1 Ipd Switch MII transmit bit 1.
71 SMTXD2 Ipd Switch MII transmit bit 2.
70 SMTXD3 Ipd Switch MII transmit bit 3.
69 SMTXEN Ipd Switch MII transmit enable.
74 SMTXER Ipd Switch MII transmit error.
1MDIXDIS I 1-5 Disable auto MDI/MDI-X.
128 TEST2 Factory test pin.
118 TESTEN Ipd Factory test pin.
7TXP1 O 1 Physical transmit signal + (differential).
13 TXP2 O 2 Physical transmit signal + (differential).
22 TXP3 O 3 Physical transmit signal + (differential).
28 TXP4 O 4 Physical transmit signal + (differential).
35 TXP5 O 5 Physical transmit signal + (differential).
8TXM1 O 1 Physical transmit signal – (differential).
14 TXM2 O 2 Physical transmit signal – (differential).
23 TXM3 O 3 Physical transmit signal – (differential).
29 TXM4 O 4 Physical transmit signal – (differential).
36 TXM5 O 5 Physical transmit signal – (differential).
123 VDDAP P 1.8V analog VDD for PLL.
3VDDAR P 1.8V analog VDD.
15 VDDAR P 1.8V analog VDD.
31 VDDAR P 1.8V analog VDD.
41 VDDAR P 1.8V analog VDD.
43 VDDAR P 1.8V analog VDD.
125 VDDAR P 1.8V analog VDD.
Notes:
1. P = Power supply.
I = Input.
O = Output.
I/O = Bidirectional.
Gnd = Ground.
Ipu = Input w/internal pull-up.
Ipd = Input w/internal pull-down.
Ipd/O = Input w/internal pull-down during reset, output pin otherwise.
Ipu/O = Input w/internal pull-up during reset, output pin otherwise.
2. PU = Strap pin pull-up.
PD = Strap pull-down.
May 2005 17 M9999-051305
KS8995XA Micrel, Inc.
Pin Number Pin Name Type(1) Port Pin Function
9VDDAT P 2.5V or 3.3V analog VDD.
18 VDDAT P 2.5V or 3.3V analog VDD.
24 VDDAT P 2.5V or 3.3V analog VDD.
37 VDDAT P 2.5V or 3.3V analog VDD.
50 VDDC P 1.8V digital core VDD.
89 VDDC P 1.8V digital core VDD.
117 VDDC P 1.8V digital core VDD.
59 VDDIO P 3.3V digital VDD for digital I/O circuitry.
77 VDDIO P 3.3V digital VDD for digital I/O circuitry.
100 VDDIO P 3.3V digital VDD for digital I/O circuitry.
121 X1 I 25MHz crystal clock connection/or 3.3V tolerant oscillator input.
Oscillator should be ±100ppm.
122 X2 O 25MHz crystal clock connection.
Note:
1. P = Power supply.
I = Input.
O = Output.
KS8995XA Micrel, Inc.
M9999-051305 18 May 2005
Pin Configuration
MDIXDIS
GNDA
VDDAR
RXP1
RXM1
GNDA
TXP1
TXM1
VDDAT
RXP2
RXM2
GNDA
TXP2
TXM2
VDDAR
GNDA
ISET
VDDAT
RXP3
RXM3
GNDA
TXP3
TXM3
VDDAT
RXP4
RXM4
GNDA
TXP4
TXM4
GNDA
VDDAR
RXP5
RXM5
GNDA
TXP5
TXM5
VDDAT
FXSD5
LED2-1
LED2-2
VDDIO
GNDD
LED3-0
LED3-1
LED3-2
LED4-0
LED4-1
LED4-2
LED5-0
LED5-1
LED5-2
VDDC
GNDD
SCONF0
SCONF1
SCRS
SCOL
SMRXD0
SMRXD1
SMRXD2
SMRXD3
SMRXDV
SMRXC
VDDIO
GNDD
SMTXC
SMTXER
SMTXD0
SMTXD1
SMTXD2
SMTXD3
SMTEXN
PCOL
PCRS
PMRXER
PMRXD0
PMRXD1
PMRXD2
PMRXD3
PMRXDV
PMRXC
VDDIO
GNDD
PMTXC
PMTXER
PMTXD0
PMTXD1
PMTXD2
PMTXD3
PMTXEN
VDDC
GNDD
RESERVE
PWRDN_N
MUX2
MUX1
GNDA
VDDAR
GNDA
VDDAR
GNDA
FXSD4
LED2-0
LED1-2
LED1-1
LED1-0
MDC
MDIO
SPIQ
SPIC/SCL
SPID/SDA
SPIS_N
PS1
PS0
RST_N
GNDD
VDDC
TESTEN
SCANEN
NC
X1
X2
VDDAP
GNDA
VDDAR
GNDA
GNDA
TEST2
65
39
1
103
128-Pin PQFP (PQ)
May 2005 19 M9999-051305
KS8995XA Micrel, Inc.
Introduction
The KS8995XA contains five 10/100 physical layer transceivers and five media access control (MAC) units with an integrated
Layer 2 switch. The device runs in three modes. The first mode is as a five-port integrated switch. The second is as a five-port
switch with the fifth port decoupled from the physical port. In this mode access to the fifth MAC is provided through a media
independent interface (MII) . This is useful for implementing an integrated broadband router. The third mode uses the dual MII
feature to recover the use of the fifth PHY. This allows the additional broadband gateway configuration, where the fifth PHY
may be accessed through the MII-P5 port.
The KS8995XA is optimized for an unmanaged design in which the configuration is achieved through I/O strapping or EEPROM
programming at system reset time.
On the media side, the KS8995XA supports IEEE 802.3 10BASE-T, 100BASE-TX on all ports, and 100BASE-FX on ports 4
and 5. The KS8995XA can be used as two separate media converters.
Physical signal transmission and reception are enhanced through the use of patented analog circuitry that makes the design
more efficient and allows for lower power consumption and smaller chip die size.
The major enhancements from the KS8995E to the KS8995XA are support for programmable rate limiting, a dual MII interface,
MDC/MDIO control interface for IEEE 802.3-defined register configuration (not all the registers), per-port broadcast storm
protection, local loopback and lower power consumption.
The KS8995XA is pin-compatible to the managed switch, the KS8995M.
Functional Overview: Physical Layer Transceiver
100BASE-TX Transmit
The 100BASE-TX transmit function performs parallel-to-serial conversion, 4B/5B coding, scrambling, NRZ-to-NRZI conver-
sion, MLT3 encoding and transmission. The circuit starts with a parallel-to-serial conversion, which converts the MII data from
the MAC into a 125MHz serial bit stream. The data and control stream is then converted into 4B/5B coding followed by a
scrambler. The serialized data is further converted from NRZ to NRZI format, and then transmitted in MLT3 current output. The
output current is set by an external 1% 3.01k resistor for the 1:1 transformer ratio. It has a typical rise/fall time of 4ns and
complies with the ANSI TP-PMD standard regarding amplitude balance, overshoot and timing jitter. The wave-shaped
10BASE-T output is also incorporated into the 100BASE-TX transmitter.
100BASE-TX Receive
The 100BASE-TX receiver function performs adaptive equalization, DC restoration, MLT3-to-NRZI conversion, data and clock
recovery, NRZI-to-NRZ conversion, de-scrambling, 4B/5B decoding and serial-to-parallel conversion. The receiving side
starts with the equalization filter to compensate for inter-symbol interference (ISI) over the twisted pair cable. Since the
amplitude loss and phase distortion is a function of the length of the cable, the equalizer has to adjust its characteristics to
optimize the performance. In this design, the variable equalizer will make an initial estimation based on comparisons of
incoming signal strength against some known cable characteristics, then it tunes itself for optimization. This is an ongoing
process and can self-adjust against environmental changes such as temperature variations.
The equalized signal then goes through a DC restoration and data conversion block. The DC restoration circuit is used to
compensate for the effect of baseline wander and improve the dynamic range. The differential data conversion circuit converts
the MLT3 format back to NRZI. The slicing threshold is also adaptive.
The clock recovery circuit extracts the 125MHz clock from the edges of the NRZI signal. This recovered clock is then used to
convert the NRZI signal into the NRZ format. The signal is then sent through the de-scrambler followed by the 4B/5B decoder.
Finally, the NRZ serial data is converted to the MII format and provided as the input data to the MAC.
PLL Clock Synthesizer
The KS8995XA generates 125MHz, 42MHz, 25MHz, and 10MHz clocks for system timing. Internal clocks are generated from
an external 25MHz crystal.
Scrambler/De-Scrambler (100BASE-TX only)
The purpose of the scrambler is to spread the power spectrum of the signal in order to reduce EMI and baseline wander. The
data is scrambled through the use of an 11-bit wide linear feedback shift register (LFSR). This can generate a 2047-bit non-
repetitive sequence. The receiver will then de-scramble the incoming data stream with the same sequence at the transmitter.
100BASE-FX Operation
100BASE-FX operation is very similar to 100BASE-TX operation except that the scrambler/de-scrambler and MLT3 encoder/
decoder are bypassed on transmission and reception. In this mode the auto-negotiation feature is bypassed since there is no
standard that supports fiber auto-negotiation.
KS8995XA Micrel, Inc.
M9999-051305 20 May 2005
100BASE-FX Signal Detection
The physical port runs in 100BASE-FX mode if FXSDx >0.6V for ports 4 and 5 only. This signal is internally referenced to
1.25V.The fiber module interface should be set by a voltage divider such that FXSDx ‘H’ is above this 1.25V reference,
indicating signal detect, and FXSDx ‘L’ is below the 1.25V reference to indicate no signal. When FXSDx is below 0.6V then
100BASE-FX mode is disabled.
100BASE-FX Far End Fault
Far end fault occurs when the signal detection is logically false from the receive fiber module. When this occurs, the
transmission side signals the other end of the link by sending 84 1’s followed by a zero in the idle period between frames. The
far end fault may be disabled through register settings.
10BASE-T Transmit
The output 10BASE-T driver is incorporated into the 100BASE-T driver to allow transmission with the same magnetics. They
are internally wave-shaped and pre-emphasized into outputs with a typical 2.3V amplitude. The harmonic contents are at least
27dB below the fundamental when driven by an all-ones Manchester-encoded signal.
10BASE-T Receive
On the receive side, input buffer and level detecting squelch circuits are employed. A differential input receiver circuit and a
PLL perform the decoding function. The Manchester-encoded data stream is separated into clock signal and NRZ data. A
squelch circuit rejects signals with levels less than 400mV or with short pulsewidths in order to prevent noises at the RXP or
RXM input from falsely triggering the decoder. When the input exceeds the squelch limit, the PLL locks onto the incoming signal
and the KS8995XA decodes a data frame. The receiver clock is maintained active during idle periods in between data
reception.
Power Management
The KS8995XA features a per port power down mode. To save power the user can power down ports that are not in use by
setting port control registers or MII control registers. In addition, it also supports full chip power down mode. When activated,
the entire chip will be shutdown.
MDI/MDI-X Auto Crossover
The KS8995XA supports MDI/MDI-X auto crossover. This facilitates the use of either a straight connection CAT-5 cable or a
crossover CAT-5 cable. The auto-sense function will detect remote transmit and receive pairs, and correctly assign the transmit
and receive pairs from the Micrel device. This can be highly useful when end users are unaware of cable types and can also
save on an additional uplink configuration connection. The auto crossover feature may be disabled through the port control
registers.
Auto-Negotiation
The KS8995XA conforms to the auto-negotiation protocol as described by the 802.3 committee. Auto-negotiation allows
unshielded twisted pair (UTP) link partners to select the best common mode of operation. In auto-negotiation the link partners
advertise capabilities across the link to each other. If auto-negotiation is not supported or the link partner to the KS8995XA
is forced to bypass auto-negotiation, then the mode is set by observing the signal at the receiver. This is known as parallel mode
because while the transmitter is sending auto-negotiation advertisements, the receiver is listening for advertisements or a fixed
signal protocol.
The flow for the link set up is depicted in Figure 4.
May 2005 21 M9999-051305
KS8995XA Micrel, Inc.
Start Auto
Negotiation
Force Link Setting
Listen for 10BaseT
Link Pulses
Listen for
100BaseTX Idles
Attempt
Auto-Negotiation
Link Mode Set
Bypass
Auto-Negotiation
and Set Link Mode
Link Mode Set ?
Parallel
Operation
Join Flow
No
Yes
Yes
No
Figure 4. Auto-Negotiation
Functional Overview: Switch Core
Address Look-Up
The internal look-up table stores MAC addresses and their associated information. It contains a 1K unicast address table plus
switching information. The KS8995XA is guaranteed to learn 1K addresses and distinguishes itself from hash-based look-up
tables which, depending on the operating environment and probabilities, may not guarantee the absolute number of addresses
it can learn.
Learning
The internal look-up engine will update its table with a new entry if the following conditions are met:
The received packet’s source address (SA) does not exist in the look-up table.
The received packet is good; the packet has no receiving errors, and is of legal length.
The look-up engine will insert the qualified SA into the table, along with the port number, time stamp. If the table is full, the
last entry of the table will be deleted first to make room for the new entry.
Migration
The internal look-up engine also monitors whether a station is moved. If it happens, it will update the table accordingly.
Migration happens when the following conditions are met:
The received packet’s SA is in the table but the associated source port information is different.
The received packet is good; the packet has no receiving errors, and is of legal length.
The look-up engine will update the existing record in the table with the new source port information.
Aging
The look-up engine will update the time stamp information of a record whenever the corresponding SA appears. The time stamp
is used in the aging process. If a record is not updated for a period of time, the look-up engine will remove the record from
the table. The look-up engine constantly performs the aging process and will continuously remove aging records. The aging
period is 300 ±75 seconds. This feature can be enabled or disabled through register 3 or by external pull-up or pull-down
resistors on LED[5][2]. See “Register 3” section.
Switching Engine
The KS8995XA features a high performance switching engine to move data to and from the MAC’s packet buffers. It operates
in store and forward mode, while the efficient switching mechanism reduces overall latency.
The KS8995XA has a 64kB internal frame buffer. This resource is shared between all five ports. The buffer sharing mode can
be programmed through Register 2. See “Register 2.” In one mode, ports are allowed to use any free buffers in the buffer pool.
In the second mode, each port is only allowed to use 1/5 of the total buffer pool. There are a total of 512 buffers available. Each
buffer is sized at 128B.
KS8995XA Micrel, Inc.
M9999-051305 22 May 2005
Media Access Controller (MAC) Operation
The KS8995XA strictly abides by IEEE 802.3 standards to maximize compatibility.
Inter-Packet Gap (IPG)
If a frame is successfully transmitted, the 96-bit time IPG is measured between the two consecutive MTXEN. If the current
packet is experiencing collision, the 96-bit time IPG is measured from MCRS and the next MTXEN.
Backoff Algorithm
The KS8995XA implements the IEEE Std. 802.3 binary exponential back-off algorithm, and optional “aggressive mode” back
off. After 16 collisions, the packet will be optionally dropped depending on the chip configuration in Register 3. See “Register
3.”
Late Collision
If a transmit packet experiences collisions after 512-bit times of the transmission, the packet will be dropped.
Illegal Frames
The KS8995XA discards frames less than 64 bytes and can be programmed to accept frames up to 1536 bytes in Register
4. For special applications, the KS8995XA can also be programmed to accept frames up to 1916 bytes in Register 4. Since
the KS8995XA supports VLAN tags, the maximum sizing is adjusted when these tags are present.
Flow Control
The KS8995XA supports standard 802.3x flow control frames on both transmit and receive sides.
On the receive side, if the KS8995XA receives a pause control frame, the KS8995XA will not transmit the next normal frame
until the timer, specified in the pause control frame, expires. If another pause frame is received before the current timer expires,
the timer will be updated with the new value in the second pause frame. During this period (being flow controlled), only flow
control packets from the KS8995XA will be transmitted.
On the transmit side, the KS8995XA has intelligent and efficient ways to determine when to invoke flow control. The flow control
is based on availability of the system resources, including available buffers, available transmit queues and available receive
queues.
The KS8995XA will flow control a port, which just received a packet, if the destination port resource is being used up. The
KS8995XA will issue a flow control frame (XOFF), containing the maximum pause time defined in IEEE standard 802.3x. Once
the resource is freed up, the KS8995XA will send out the other flow control frame (XON) with zero pause time to turn off the
flow control (turn on transmission to the port). A hysteresis feature is provided to prevent the flow control mechanism from being
activated and deactivated too many times.
The KS8995XA will flow control all ports if the receive queue becomes full.
Half-Duplex Back Pressure
A half-duplex back pressure option (note: not in 802.3 standards) is also provided. The activation and deactivation conditions
are the same as the above in full-duplex mode. If back pressure is required, the KS8995XA will send preambles to defer the
other stations’ transmission (carrier sense deference). To avoid jabber and excessive deference defined in 802.3 standard,
after a certain time it will discontinue the carrier sense but it will raise the carrier sense quickly. This short silent time (no carrier
sense) is to prevent other stations from sending out packets and keeps other stations in carrier sense deferred state. If the port
has packets to send during a back pressure situation, the carrier-sense-type back pressure will be interrupted and those
packets will be transmitted instead. If there are no more packets to send, carrier-sense-type back pressure will be active again
until switch resources are free. If a collision occurs, the binary exponential back-off algorithm is skipped and carrier sense is
generated immediately, reducing the chance of further colliding and maintaining carrier sense to prevent reception of packets.
To ensure no packet loss in 10BASE-T or 100BASE-TX half-duplex modes, the user must enable the following:
Aggressive backoff (register 3, bit 0)
No excessive collision drop (register 4, bit 3)
Back pressure (register 4, bit 5)
These bits are not set as the default because this is not the IEEE standard.
May 2005 23 M9999-051305
KS8995XA Micrel, Inc.
Broadcast Storm Protection
The KS8995XA has an intelligent option to protect the switch system from receiving too many broadcast packets. Broadcast
packets will be forwarded to all ports except the source port, and thus use too many switch resources (bandwidth and available
space in transmit queues). The KS8995XA has the option to include “multicast packets” for storm control. The broadcast storm
rate parameters are programmed globally, and can be enabled or disabled on a per port basis. The rate is based on a 50ms
interval for 100BT and a 500ms interval for 10BT. At the beginning of each interval, the counter is cleared to zero, and the rate
limit mechanism starts to count the number of bytes during the interval. The rate definition is described in Register 6 and
Register 7. The default setting for registers 6 and 7 is 0x4A, which is 74 decimal. This is equal to a rate of 1%, calculated as
follows:
148,800 frames/sec × 50ms/interval × 1% = 74 frames/interval (approx.) = 0x4A
MII Interface Operation
The media independent interface (MII) is specified by the IEEE 802.3 committee and provides a common interface between
physical layer and MAC layer devices. The KS8995XA provides two such interfaces. The MII-P5 interface is used to connect
to the fifth PHY, whereas the MII-SW interface is used to connect to the fifth MAC. Each of these MII interfaces contains two
distinct groups of signals, one for transmission and the other for receiving. The table below describes the signals used in the
MII-P5 interface.
The MII-P5 interface operates in PHY mode only, while the MII-SW interface operates in either MAC mode or PHY mode. These
interfaces are nibble-wide data interfaces and therefore run at 1/4 the network bit rate (not encoded). Additional signals on the
transmit side indicate when data is valid or when an error occurs during transmission. Likewise, the receive side has indicators
that convey when the data is valid and without physical layer errors. For half-duplex operation, there is a signal that indicates
a collision has occurred during transmission.
Note that the signal MRXER is not provided on the MII-SW interface for PHY mode operation and the signal MTXER is not
provided on the MII-SW interface for MAC mode operation. Normally MRXER would indicate a receive error coming from the
physical layer device. MTXER would indicate a transmit error from the MAC device. These signals are not appropriate for this
configuration. For PHY mode operation, if the device interfacing with the KS8995XA has an MRXER pin, it should be tied low.
For MAC mode operation, if the device interfacing with the KS8995XA has an MTXER pin, it should be tied low.
MII Signal Description KS8995XA Signal
MTXEN Transmit enable PMTXEN
MTXER Transmit error PMTXER
MTXD3 Transmit data bit 3 PMTXD[3]
MTXD2 Transmit data bit 2 PMTXD[2]
MTXD1 Transmit data bit 1 PMTXD[1]
MTXD0 Transmit data bit 0 PMTXD[0]
MTXC Transmit clock PMTXC
MCOL Collision detection PCOL
MCRS Carrier sense PCRS
MRXDV Receive data valid PMRXDV
MRXER Receive error PMRXER
MRXD3 Receive data bit 3 PMRXD[3]
MRXD2 Receive data bit 2 PMRXD[2]
MRXD1 Receive data bit 1 PMRXD[1]
MRXD0 Receive data bit 0 PMRXD[0]
MRXC Receive clock PMRXC
MDC Management data clock MDC
MDIO Management data I/O MDIO
Table 1. MII P5 Signals (PHY Mode)
KS8995XA Micrel, Inc.
M9999-051305 24 May 2005
PHY Mode Connection MAC Mode Connection
External KS8995XA External KS8995XA
MAC Signal Description PHY Signal
MTXEN SMTXEN Transmit enable MTXEN SMRXDV
MTXER SMTXER Transmit error MTXER Not used
MTXD3 SMTXD[3] Transmit data bit 3 MTXD3 SMRXD[3]
MTXD2 SMTXD[2] Transmit data bit 2 MTXD2 SMRXD[2]
MTXD1 SMTXD[1] Transmit data bit 1 MTXD1 SMRXD[1]
MTXD0 SMTXD[0] Transmit data bit 0 MTXD0 SMRXD[0]
MTXC SMTXC Transmit clock MTXC SMRXC
MCOL SCOL Collision detection MCOL SCOL
MCRS SCRS Carrier sense MCRS SCRS
MRXDV SMRXDV Receive data valid MRXDV SMTXEN
MRXER Not used Receive error MRXER SMTXER
MRXD3 SMRXD[3] Receive data bit 3 MRXD3 SMTXD[3]
MRXD2 SMRXD[2] Receive data bit 2 MRXD2 SMTXD[2]
MRXD1 SMRXD[1] Receive data bit 1 MRXD1 SMTXD[1]
MRXD0 SMRXD[0] Receive data bit 0 MRXD0 SMTXD[0]
MRXC SMRXC Receive clock MRXC SMTXC
Table 2. MII SW Signals
May 2005 25 M9999-051305
KS8995XA Micrel, Inc.
SNI Interface Operation
The serial network interface (SNI) is compatible with some controllers used for network layer protocol processing. This interface
can be directly connected to these types of devices. The signals are divided into two groups, one for transmission and the other
for reception. The signals involved are described in the table below.
SNI Signal Description KS8995XA Signal
TXEN Transmit Enable SMTXEN
TXD Serial Transmit Data SMTXD[0]
TXC Transmit Clock SMTXC
COL Collision Detection SCOL
CRS Carrier Sense SMRXDV
RXD Serial Receive Data SMRXD[0]
RXC Receive Clock SMRXC
Table 3. SNI Signals
This interface is a bit-wide data interface and therefore runs at the network bit rate (not encoded). An additional signal on the
transmit side indicates when data is valid. Likewise, the receive side has an indicator that conveys when the data is valid.
For half-duplex operation there is a signal that indicates a collision has occurred during transmission.
Advanced Functionality
QoS Support
The KS8995XA is a QoS switch, meaning that is it able to identify selected packets on its ingress ports, prioritize them, and
service the packets according to their priority on the egress ports. In this way, the KS8995XA can provide statistically better
service to the high priority packets that are latency sensitive, or require higher bandwidth. The KS8995XA supports ingress
QoS classification using three different mechanisms: port-based priority, 802.1p tag-based priority, and DSCP priority for IPv4
packets.
Port-based priority is useful when the user wants to give a device on a given port high priority. For example in Figure 7, port
1 is given high priority because it is connected to an IP phone and port 4 is given lower priority because it is connected to a
computer whose data traffic may be less sensitive to network congestion. Each port on the KS8995XA can be set as high or
low priority with an EEPROM. The port priority is set in bit 4 of registers 0x10, 0x20, 0x30, 0x40, 0x50 for ports 1, 2, 3, 4 and
5, respectively. Port-based priority is overridden by the OR’ed result of the 802.1p and DSCP priorities if they are all enabled
at the same time.
P3 P4
Low
4[3
P
P
ri o P
P1[3]=1
High Priority Port
WAN
Router
8995XA
P5
P1 P2
P5[0]=1, Hi/Lo Tx Priority
Queues enabled
Hi-Pri
Queue
Lo-Pri
Queue
]=0
rio ty rt
IP Phone
Figure 7. Port-Based Priority
KS8995XA Micrel, Inc.
M9999-051305 26 May 2005
The KS8995XA can classify tagged packets using the 802.1p tag-based priority. In this prioritization scheme, the user can
enable the 802.1p classification on a per port basis in bit 5 of registers 0x10, 0x20, 0x30, 0x40 and 0x50 for ports 1, 2, 3, 4,
and 5, respectively. Then the user specifies the 802.1p base priority in register 0x02, bits [6-4]. When a tagged packet is
received, the KS8995XA examines the 3 bit 802.1p priority field shown in Figure 8. These 3 bits are compared against the base
priority. The prioritization policy is as follows:
Comparison Priority
802.1p Priority Base Priority High
802.1p Priority < Base Priority Low
Table 4. 802.1p Priority
Preamble DA SA TCI
8664
Length LLC Data CRC
246-1500 4
1
Tagged Packet Type
(8100 for Ethernet) 802.1p
CFI
VLAN ID
Bytes
Bits 16 3 12
Figure 8. 802.3 Tagged Packet
VIP
Siz
ader
46
4
Preamble DA SA Tag
866
Type Data CRC
246-1500 4
Bytes
Bits
er.
0x4 DiffServ Res.
2
He
e
42
Figure 9. IPv4 Packet
In order to support QoS from end-to-end in a network, the KS8995XA can also classify packets based on the IPv4 DiffServ
field shown in Figure 9.
The DiffServ field consists of 6 bits, which can be used to specify 64 code points. The KS8995XA provides 64 bits (DSCP[63:0])
in 8 registers (0x60 to 0x67), in which the user specifies the priority of each of the 64 code points. The DiffServ classification
is enabled on a per port basis in bit 6 of registers 0x10, 0x20, 0x30, 0x40 and 0x50 for ports 1, 2, 3, 4, and 5, respectively. If
the DiffServ classification is enabled on a port, the KS8995XA will decode the IPv4 DiffServ field and look at the user defined
code point bit to determine if the packet is high priority or low priority. If the code point is a ‘1’, the packet is high priority. If the
code point is ‘0’, the packet is low priority.
May 2005 27 M9999-051305
KS8995XA Micrel, Inc.
DiffServ Field (Binary) Code Point KS8995X (Reg. and Bit)
000000 DSCP[0] 0x67, bit 0
000001 DSCP[1] 0x67, bit 1
000010 DSCP[2] 0x67, bit 2
000011 DSCP[3] 0x67, bit 3
000100 DSCP[4] 0x67, bit 4
•••
•••
•••
111011 DSCP[59] 0x60, bit 3
111100 DSCP[60] 0x60, bit 4
111101 DSCP[61] 0x60, bit 5
111110 DSCP[62] 0x60, bit 6
111111 DSCP[63] 0x60, bit 7
Table 5. DiffServ Code Point
Once classification of the packets has been determined either by port-based priority, 802.1p tag-based priority or DiffServ
priority, they are placed in either the high or low priority queue on the egress port. The user can enable the egress priority queues
on a per port basis by setting bit 0 of registers 0x10, 0x20, 0x30, 0x40, and 0x50 for ports 1, 2, 3, 4 and 5, respectively. If the
egress priority queue for a given port is not set, the port will treat all packets as if they are the same priority, even though packets
are classified on their ingress ports. If the egress priority queue for a given port is enabled, packets are serviced based on the
user programmable egress policy. The priority scheme selection is set in register 0x05 bits[3-2] as shown in Table 6.
Register Register
0x05, bit 3 0x05, bit 2 Egress Priority Scheme
00Always deliver high priority packets first
01Deliver high/low priority packets at a ratio of 10/1
10Deliver high/low priority packets at a ratio of 5/1
11Deliver high/low priority packets at a ratio of 2/1
Table 6. Transmit Priority Ratio
The KS8995XA offers support for port-based, 802.1p tag-based, and IPv4 DiffServ priority, as well as programmable egress
policies. These KS8995XA QoS features enable identifying, classifying and forwarding packets based on their priority. The
system designer is able to use this device to build network elements that give more control over system resources, priority
service to mission critical applications, and can be integrated into the next generation of multimedia networks.
Rate Limit Support
KS8995XA supports hardware rate limiting on “receive” and “transmit” independently on a per port basis. It also supports rate
limiting in a priority or non-priority environment. The rate limit starts from 0Kbps and goes up to the line rate in steps of 32Kbps.
The KS8995XA uses one second as an interval. At the beginning of each interval, the counter is cleared to zero, and the rate
limit mechanism starts to count the number of bytes during this interval.
For receive, if the number of bytes exceeds the programmed limit, the switch will stop receiving packets on the port until the
“one second” interval expires. There is an option provided for flow control to prevent packet loss. If the rate limit is programmed
greater than or equal to 128Kbps and the byte counter is 8K bytes below the limit, the flow control will be triggered. If the rate
limit is programmed lower than 128Kbps and the byte counter is 2K bytes below the limit, the flow control will be triggered.
For transmit, if the number of bytes exceeds the programmed limit, the switch will stop transmitting packets on the port until
the “one second” interval expires.
If priority is enabled, the KS8995XA can support different rate controls for both high priority and low priority packets. This can
be programmed through Registers 21 – 27.
KS8995XA Micrel, Inc.
M9999-051305 28 May 2005
Configuration Interface
The KS8995XA functions as a unmanaged switch. If no EEPROM exists, the KS8995XA will operate from its default and strap-
in settings.
I2C Master Serial Bus Configuration
If a 2-wire EEPROM exists, the KS8995XA can perform more advanced features like broadcast storm protection and rate
control. The EEPROM should have the entire valid configuration data from register 0 to register 109 defined in the memory
map, except the status registers. The configuration access time (tprgm) is less than 15ms as shown in Figure 10.
....
....
....
RST_N
SCL
SDA
t
prgm<15 ms
Figure 10. EEPROM Configuration Timing Diagram
To configure the KS8995XA with a pre-configured EEPROM use the following steps:
•At the board level, connect pin 110 on the KS8995XA to the SCL pin on the EEPROM. Connect pin 111 on the
KS8995XA to the SDA pin on the EEPROM.
Be sure the board-level reset signal is connected to the KS8995XA reset signal on pin 115 (RST_N).
•Program the contents of the EEPROM before placing it on the board with the desired configuration data. Note that
the first byte in the EEPROM must be “95” for the loading to occur properly. If this value is not correct, all other data
will be ignored.
•Place EEPROM on the board and power up the board. Assert the active-low board level reset to RST_N on the
KS8995XA. After the reset is de-asserted, the KS8995XA will begin reading configuration data from the EEPROM.
The configuration access time (tprgm) is less than 15ms.
Note: For proper operation, make sure pin 47 (PWRDN_N) is not asserted during the reset operation.
MII Management Interface (MIIM)
A standard MIIM interface is provided for all five PHY devices in the KS8995XA. An external device with MDC/MDIO capability
is able to read PHY status or to configure PHY settings. For details on the MIIM interface standard, please reference the IEEE
802.3 specification (section 22.2.4.5). The MIIM interface does not have access to all the configuration registers in the
KS8995XA. It can only access the standard MII registers. See “MIIM Registers” section.
May 2005 29 M9999-051305
KS8995XA Micrel, Inc.
Register Map
Offset
Decimal Hex Description
0-1 0x00-0x01 Chip ID Registers
2-11 0x02-0x0B Global Control Registers
12-15 0x0C-0x0F Reserved
16-29 0x10-0x1D Port 1 Control Registers
30-31 0x1E-0x2F Port 1 Status Registers
32-45 0x20-0x2D Port 2 Control Registers
46-47 0x2E-0x2F Port 2 Status Registers
48-61 0x30-0x3D Port 3 Control Registers
62-63 0x3E-0x3F Port 3 Status Registers
64-77 0x40-0x4D Port 4 Control Registers
78-79 0x4E-0x4F Port 4 Status Registers
80-93 0x50-0x5D Port 5 Control Registers
94-95 0x5E-0x5F Port 5 Status Registers
96-103 0x60-0x67 TOS Priority Control Registers
104-109 0x68-0x6D MAC Address Registers
Global Registers
Address Name Description Mode Default
Register 0 (0x00): Chip ID0
7-0 Family ID Chip family RO 0x95
Register 1 (0x01): Chip ID1/Start Switch
7-4 Chip ID 0x0 is assigned to 95 series. (95XA) RO 0x0
3-1 Revision ID Revision ID RO 0x2
0Start switch The chip starts automatically after trying to read the RW
external EEPROM. If EEPROM does not exist, the
chip will use default values for all internal registers. If
EEPROM is present, the contents in the EEPROM will
be checked. The switch will check: (1) Register 0 =
0x95, (2) Register 1 [7:4] = 0x0. If this check is OK,
the contents in the EEPROM will override chip register
default values.
Register 2 (0x02): Global Control 0
7Reserved Reserved R/W 0x0
6-4 802.1p base priority Used to classify priority for incoming 802.1q packets. R/W 0x4
“User priority” is compared against this value
: classified as high priority
< : classified as low priority
3Enable PHY MII 1 = enable PHY MII interface R/W Pin LED[5][1] strap
(note: if not enabled, the switch will tri-state all outputs.) option. Pull-down
(0): isolate. Pull-up
(1): Enable.
Note: LED[5][1]
has internal pull-up.
KS8995XA Micrel, Inc.
M9999-051305 30 May 2005
Address Name Description Mode Default
Register 2 (0x02): Global Control 0 (continued)
2 Buffer share mode 1 = buffer pool is shared by all ports. A port can use R/W 0x1
more buffer when other ports are not busy.
0 = a port is only allowed to use 1/5 of the buffer pool.
1UNH mode 1 = the switch will drop packets with 0x8808 in T/L R/W 0
filed, or DA=01-80-C2-00-00-01.
0 = the switch will drop packets qualified as
“flow control” packets.
0Link change age 1 = link change from “link” to “no link” will cause fast R/W 0
aging (<800µs) to age address table faster. After an
age cycle is complete, the age logic will return to
normal (300 ±75 seconds). Note: If any port is
unplugged, all addresses will be automatically aged
out.
Register 3 (0x03): Global Control 1
7Pass all frames 1 = switch all packets including bad ones. Used solely R/W 0
for debugging purpose. Works in conjunction with
sniffer mode.
6Reserved Reserved R/W 0
5IEEE 802.3x transmit 0 = will enable transmit flow control based on AN result R/W Pin PMRXD3 strap
flow control disable 1 = will not enable transmit flow control regardless of option. Pull-down (0):
AN result. Enable TX flow
control. Pull-up (1):
Disable TX/RX flow
control.
Note: PMRXD3
has internal pull-
down.
4IEEE 802.3x receive 0 = will enable receive flow control based on AN result R/W Pin PMRXD3 strap
flow control disable 1 = will not enable receive flow control regardless of option. Pull-down (0):
AN result. Enable RX flow
control. Pull-up (1):
Note: Bit 5 and bit 4 default values are controlled by Disable TX/RX flow
the same pin, but they can be programmed control.
independently. Note: PMRXD3
has internal pull-
down.
3Frame length field 1 = will check frame length field in the IEEE packets. R/W 0
check If the actual length does not match, the packet will be
dropped. (for L/T < 1500)
2Aging enable 1 = Enable age function in the chip R/W Pin LED[5][2] strap
0 = Disable aging function option. Pull-down
(0): Aging disable.
Pull-up (1): Aging
Enable.
Note: LED[5][2]
has internal pull-up.
1 Fast age enable 1 = turn on fast age (800µs) R/W 0
0Aggressive back 1 = enable more aggressive back off algorithm in half- R/W Pin PMRXD0 strap
off enable duplex mode to enhance performance. This is not an option. Pull-down (0):
IEEE standard. Disable aggressive
back off. Pull-up
(1): Aggressive
backoff. Note:
PMRXD0
has internal pull-
down.
May 2005 31 M9999-051305
KS8995XA Micrel, Inc.
Address Name Description Mode Default
Register 4 (0x04): Global Control 2
7Reserved Reserved R/W 1
6Multicast storm 1 = “Broadcast Storm Protection” does not include R/W 1
protection disable multicast packets. Only DA=FFFFFFFFFFFF packets
will be regulated.
0 = “Broadcast Storm Protection” includes DA =
FFFFFFFFFFFF and DA[40] = 1 packets.
5Reserved Reserved R/W 1
4Flow control and back 1 = fair mode is selected. In this mode, if a flow control R/W 1
pressure fair mode port and a non-flow control port talk to the same
destination port, packets from the non-flow control port
may be dropped. This is to prevent the flow control port
from being flow controlled for an extended period of time.
0 = in this mode, if a flow control port and a non-flow
control port talk to the same destination port, the flow
control port will be flow controlled. This may not be “fair”
to the flow control port.
3No excessive collision 1 = the switch will not drop packets when 16 or more R/W Pin PMRXD1 strap
drop collisions occur. option. Pull-down (0):
0 = the switch will drop packets when 16 or more Drop excessive
collisions occur. collision packets.
Pull-up (1): Don’t
drop excessive
collision packets.
Note: PMRXD1
has internal pull-
down.
2Huge packet support 1 = will accept packet sizes up to 1916 bytes (inclusive). R/W 0
This bit setting will override setting from bit 1 of the
same register.
0 = the max packet size will be determined by bit 1 of
this register.
1Legal maximum packet 1 = will accept packet sizes up to 1536 bytes (inclusive). R/W Pin PMRXER strap
size check disable 0 = 1522 bytes for tagged packets (not including. option. Pull-down (0):
packets with STPID from CPU to ports 1-4), 1518 bytes 1518/1522 byte
for untagged packets. Any packets larger than the packets. Pull-up
specified value will be dropped. value will be
dropped. (1): 1536
byte packets
Note: PMRXER
has internal pull
down.
0Priority buffer reserve 1 = each output queue is pre-allocated 48 buffers, R/W 0
used exclusively for high priority packets. It is
recommended to enable this when priority queue
feature is turned on.
0 = no reserved buffers for high priority packets.
Register 5 (0x05): Global Control 3
7Reserved Reserved R/W 0
6Reserved Reserved R/W 0
5Reserved Reserved R/W 0
4Reserved Reserved R/W 0
3-2 Priority scheme select 00 = always deliver high priority packets first. R/W 00
01 = deliver high/low packets at ratio 10/1.
10 = deliver high/low packets at ratio 5/1.
11 = deliver high/low packets at ratio 2/1.
KS8995XA Micrel, Inc.
M9999-051305 32 May 2005
Address Name Description Mode Default
Register 5 (0x05): Global Control 3 (continued)
1Reserved Reserved R/W 0
0Sniff mode select 1 = will do Rx AND Tx sniff (both source port and R/W 0
destination port need to match).
0 = will do Rx OR Tx sniff (either source port or
destination port needs to match). This is the mode
used to implement Rx only sniff.
Register 6 (0x06): Global Control 4
7Switch MII back 1 = enable half-duplex back pressure on switch MII R/W 0
pressure enable interface.
0 = disable back pressure on switch MII interface.
6Switch MII half 1 = enable MII interface half-duplex mode. R/W Pin SMRXD2 strap
duplex mode 0 = enable MII interface full-duplex mode. option. Pull-down (0):
Full-duplex mode.
Pull-up (1): Half-
duplex mode.
Note: SMRXD2
has internal pull-
down.
5Switch MII flow 1 = enable full-duplex flow control on switch MII interface. R/W Pin SMRXD3 strap
control enable 0 = disable full-duplex flow control on switch MII interface. option. Pull-down
(0): disable flow
control. Pull-up (1):
enable flow control
Note: SMRXD3
has internal pull-
down.
4 Switch MII 10BT 1 = the switch interface is in 10Mbps mode. R/W Pin SMRXD1 strap
0 = the switch interface is in 100Mbps mode. option. Pull-down (0):
Enable 100Mbps
Pull-up (1): Enable
10Mpbs.
Note: SMRXD1 has
internal pull-down.
3 Null VID replacement 1 = will replace null VID with port VID (12 bits). R/W 0
0 = no replacement for null VID.
2-0 Broadcast storm This along with the next register determines how many R/W 000
protection rate bit [10:8] “64 byte blocks” of packet data allowed on an input
port in a preset period. The period is 50ms for 100BT
or 500ms for 10BT. The default is 1%.
Register 7 (0x07): Global Control 5
7-0 Broadcast storm This along with the previous register determines how R/W 0x4A(1)
protection rate bit [7:0] many “64 byte blocks” of packet data are allowed on
an input port in a preset period. The period is 50ms
for 100BT or 500ms for 10BT. The default is 1%.
Note:
1. 148,800 frames/sec × 50ms/interval × 1% = 74 frames/interval (approx.) = 0x4A.
Register 8 (0x08): Global Control 6
7-0 Factory testing Reserved R/W 0x24
Register 9 (0x09): Global Control 7
7-0 Factory testing Reserved R/W 0x24
Register 10 (0x0A): Global Control 8
7-0 Factory testing Reserved R/W 0x24
May 2005 33 M9999-051305
KS8995XA Micrel, Inc.
Address Name Description Mode Default
Register 11 (0x0B): Global Control 9
7-4 Reserved N/A 0
3PHY power save 0 = disable PHY power save mode. R/W 0
1 = enable PHY power save mode.
2Factory setting Reserved R/W 0
1LED mode 0 = led mode 0 R/W Pin SMRXD0 strap
1 = led mode 1 option. Pull-down(0):
Enabled led mode 0.
Pull-up(1): Enabled.
led mode 1.
Note: SMRXD0 has
internal pull-down 0.
Mode 0 Mode 1
LEDX_2 Lnk/Act 100Lnk/Act
LEDX_1 Fulld/Col 10Lnk/Act
LEDX_0 Speed Fulld
0Reserved Reserved RW 0
Port Registers
The following registers are used to enable features that are assigned on a per port basis. The register bit assignments are
the same for all ports, but the address for each port is different, as indicated.
Register 16 (0x10): Port 1 Control 0
Register 32 (0x20): Port 2 Control 0
Register 48 (0x30): Port 3 Control 0
Register 64 (0x40): Port 4 Control 0
Register 80 (0x50): Port 5 Control 0
Address Name Description Mode Default
7Broadcast storm 1 = enable broadcast storm protection for ingress R/W 0
protection enable packets on the port.
0 = disable broadcast storm protection.
6 DiffServ priority 1 = enable DiffServ priority classification for ingress R/W 0
classification enable packets on port.
0 = disable DiffServ function.
5802.1p priority 1 = enable 802.1p priority classification for ingress R/W 0
classification enable packets on port.
0 = disable 802.1p.
4Port-based priority 1 = ingress packets on the port will be classified as high R/W 0
classification enable priority if “DiffServ” or “802.1p” classification is not
enabled or fails to classify.
0 = ingress packets on port will be classified as low
priority if “DiffServ” or “802.1p” classification is not
enabled or fails to classify.
Note: “DiffServ”, “802.1p” and port priority can be
enabled at the same time. The OR’ed result of 802.1p
and DSCP overwrites the port priority.
3Reserved Reserved R/W 0
2 Tag insertion 1 = when packets are output on the port, the switch will R/W 0
add 802.1q tags to packets without 802.1q tags when
received. The switch will not add tags to packets already
tagged. The tag inserted is the ingress port’s “port VID.”
0 = disable tag insertion.
KS8995XA Micrel, Inc.
M9999-051305 34 May 2005
Address Name Description Mode Default
1 Tag removal 1 = when packets are output on the port, the switch R/W 0
will remove 802.1q tags from packets with 802.1q tags
when received. The switch will not modify packets
received without tags.
0 = disable tag removal.
0Priority enable 1 = the port output queue is split into high and low R/W 0
priority queues.
0 = single output queue on the port. There is no priority
differentiation even though packets are classified into
high or low priority.
Register 17 (0x11): Port 1 Control 1
Register 33 (0x21): Port 2 Control 1
Register 49 (0x31): Port 3 Control 1
Register 65 (0x41): Port 4 Control 1
Register 81 (0x51): Port 5 Control 1
Address Name Description Mode Default
7Sniffer port 1 = port is designated as sniffer port and will transmit R/W 0
packets that are monitored.
0 = port is a normal port.
6Receive sniff 1 = all the packets received on the port will be marked R/W 0
as “monitored packets” and forwarded to the designated
“sniffer port.”
0 = no receive monitoring.
5 Transmit sniff 1 = all the packets transmitted on the port will be R/W 0
marked as “monitored packets” and forwarded to the
designated “sniffer port.”
0 = no transmit monitoring.
4-0 Port VLAN membership Define the port’s Port VLAN membership. Bit 4 stands R/W 0x1f
for port 5, bit 3 for port 4...bit 0 for port 1. The port can
only communicate within the membership. A ‘1’
includes a port in the membership, a ‘0’ excludes a port
from membership.
Register 18 (0x12): Port 1 Control 2
Register 34 (0x22): Port 2 Control 2
Register 50 (0x32): Port 3 Control 2
Register 66 (0x42): Port 4 Control 2
Register 82 (0x52): Port 5 Control 2
Address Name Description Mode Default
7Reserved Reserved 0x0
6Reserved Reserved R/W 0
5Discard non-PVID 1 = the switch will discard packets whose VID does R/W 0
packets not match ingress port default VID.
0 = no packets will be discarded.
4Force flow control 1 = will always enable Rx and Tx flow control on the R/W 0
port, regardless of AN result. For port 4 only,
0 = the flow control is enabled based on AN result. there is a special
configuration pin to
Note: Setting a port for both half-duplex and forced set the default, Pin
flow control is an illegal configuration. For half-duplex PCOL strap option.
enable back pressure. Pull-down (0): No
force flow control.
Pull-up (1): Force
flow control.
Note: PCOL has
internal pull-down.
May 2005 35 M9999-051305
KS8995XA Micrel, Inc.
Address Name Description Mode Default
3Back pressure enable 1 = enable port half-duplex back pressure. R/W Pin PMRXD2 strap
0 = disable port half-duplex back pressure. option. Pull-down (0):
disable back
pressure. Pull-up(1):
enable back
pressure.
Note: PMRXD2 has
internal pull-down.
2Transmit enable 1 = enable packet transmission on the port. R/W 1
0 = disable packet transmission on the port.
1 Receive enable 1 = enable packet reception on the port. R/W 1
0 = disable packet reception on the port.
0 Learning disable 1 = disable switch address learning capability. R/W 0
0 = enable switch address learning.
Register 19 (0x13): Port 1 Control 3
Register 35 (0x23): Port 2 Control 3
Register 51 (0x33): Port 3 Control 3
Register 67 (0x43): Port 4 Control 3
Register 83 (0x53): Port 5 Control 3
Address Name Description Mode Default
7-0 Default tag [15:8] Port’s default tag, containing: R/W 0
7-5: user priority bits
4: CFI bit
3-0 : VID[11:8]
Register 20 (0x14): Port 1 Control 4
Register 36 (0x24): Port 2 Control 4
Register 52 (0x34): Port 3 Control 4
Register 68 (0x44): Port 4 Control 4
Register 84 (0x54): Port 5 Control 4
Address Name Description Mode Default
7-0 Default tag [7:0] Default port 1’s tag, containing: R/W 1
7-0: VID[7:0]
Note:
Registers 19 and 20 (and those corresponding to other ports) serve two purposes: (1) Associated with the ingress untagged packets, and used for
egress tagging; (2) Default VID for the ingress untagged or null-VID-tagged packets, and used for address look up.
Register 21 (0x15): Port 1 Control 5
Register 37 (0x25): Port 2 Control 5
Register 53 (0x35): Port 3 Control 5
Register 69 (0x45): Port 4 Control 5
Register 85 (0x55): Port 5 Control 5
Address Name Description Mode Default
7-0 Transmit high priority This along with port control 7, bits [3:0] form a 12-bit R/W 0
rate control [7:0] field to determine how many “32Kbps” high priority
blocks can be transmitted (in a unit of 4K bytes in a
one second period).
Register 22 (0x16): Port 1 Control 6
Register 38 (0x26): Port 2 Control 6
Register 54 (0x36): Port 3 Control 6
Register 70 (0x46): Port 4 Control 6
Register 86 (0x56): Port 5 Control 6
Address Name Description Mode Default
7-0 Transmit low priority This along with port control 7, bits [7:4] form a 12-bit R/W 0
rate control [7:0] field to determine how many “32Kbps” low priority
blocks can be transmitted (in a unit of 4K bytes in a
one second period).
KS8995XA Micrel, Inc.
M9999-051305 36 May 2005
Register 23 (0x17): Port 1 Control 7
Register 39 (0x27): Port 2 Control 7
Register 55 (0x37): Port 3 Control 7
Register 71 (0x47): Port 4 Control 7
Register 87 (0x57): Port 5 Control 7
Address Name Description Mode Default
7-4 Transmit low priority This along with port control 6, bits [7:0] form a 12-bit R/W 0
rate control [11:8] field to determine how many “32Kbps” low priority
blocks can be transmitted (in a unit of 4K bytes in a
one second period).
3-0 Transmit high priority This along with port control 5, bits [7:0] form a 12-bit R/W 0
rate control [11:8] field to determine how many “32Kbps” high priority
blocks can be transmitted (in unit of 4K bytes in a
one second period).
Register 24 (0x18): Port 1 Control 8
Register 40 (0x28): Port 2 Control 8
Register 56 (0x38): Port 3 Control 8
Register 72 (0x48): Port 4 Control 8
Register 88 (0x58): Port 5 Control 8
Address Name Description Mode Default
7-0 Receive high priority This along with port control 10, bits [3:0] form a 12-bit R/W 0
rate control [7:0] field to determine how many “32Kbps” high priority
blocks can be received (in a unit of 4K bytes in a one
second period).
Register 25 (0x19): Port 1 Control 9
Register 41 (0x29): Port 2 Control 9
Register 57 (0x39): Port 3 Control 9
Register 73 (0x49): Port 4 Control 9
Register 89 (0x59): Port 5 Control 9
Address Name Description Mode Default
7-0 Receive low priority This along with port control 10, bits [7:4] form a 12-bit R/W 0
rate control [7:0] field to determine how many “32Kbps” low priority
blocks can be received (in a unit of 4K bytes in a one
second period).
Register 26 (0x1A): Port 1 Control 10
Register 42 (0x2A): Port 2 Control 10
Register 58 (0x3A): Port 3 Control 10
Register 74 (0x4A): Port 4 Control 10
Register 90 (0x5A): Port 5 Control 10
Address Name Description Mode Default
7-4 Receive low priority This along with port control 9, bits [7:0] form a 12-bit R/W 0
rate control [11:8] field to determine how many “32Kbps” low priority
blocks can be received (in a unit of 4K bytes in a one
second period).
3-0 Receive high priority This along with port control 8, bits [7:0] form a 12-bit R/W 0
rate control [11:8] field to determine how many “32Kbps” high priority
blocks can be received (in a unit of 4K bytes in a one
second period).
May 2005 37 M9999-051305
KS8995XA Micrel, Inc.
Register 27 (0x1B): Port 1 Control 11
Register 43 (0x2B): Port 2 Control 11
Register 59 (0x3B): Port 3 Control 11
Register 75 (0x4B): Port 4 Control 11
Register 91 (0x5B): Port 5 Control 11
Address Name Description Mode Default
7 Receive differential 1 = If bit 6 is also ‘1’ this will enable receive rate control R/W 0
priority rate control for this port on low priority packets at the low priority
rate. If bit 5 is also ‘1’, this will enable receive rate
control on high priority packets at the high priority rate.
0 = receive rate control will be based on the low priority
rate for all packets on this port.
6Low priority receive 1 = enable port’s low priority receive rate control feature. R/W 0
rate control enable 0 = disable port’s low priority receive rate control.
5 High priority receive 1 = if bit 7 is also ‘1’ this will enable the port’s high R/W 0
rate control enable priority receive rate control feature. If bit 7 is a ‘0’ and
bit 6 is a ‘1’, all receive packets on this port will be rate
controlled at the low priority rate.
0 = disable port’s high priority receive rate control feature.
4Low priority receive rate 1 = flow control may be asserted if the port’s low priority R/W 0
flow control enable receive rate is exceeded.
0 = flow control is not asserted if the port’s low priority
receive rate is exceeded.
3High priority receive 1 = flow control may be asserted if the port’s high R/W 0
rate flow control enable priority receive rate is exceeded. To use this, differential
receive rate control must be on.
0 = flow control is not asserted if the port’s high
priority receive rate is exceeded.
2Transmit differential 1 = transmit rate control on both high and low R/W 0
priority rate control priority packets based on the rate counters defined by
the high and low priority packets respectively.
0 = transmit rate control on any packets.
The rate counters defined in low priority will be used.
1Low priority transmit 1 = enable the port’s low priority transmit rate control R/W 0
rate control enable feature.
0 = disable the port’s low priority transmit rate control
feature.
0High priority transmit 1 = enable the port’s high priority transmit rate control R/W 0
rate control enable feature.
0 = disable the port’s high priority transmit rate control
feature.
Register 28 (0x1C): Port 1 Control 12
Register 44 (0x2C): Port 2 Control 12
Register 60 (0x3C): Port 3 Control 12
Register 76 (0x4C): Port 4 Control 12
Register 92 (0x5C): Port 5 Control 12
Note:
Port Control 12 and 13, and Port Status 0 contents can be accessed by MIIM (MDC/MDIO) interface via the standard MIIM register definition.
Address Name Description Mode Default
7Disable auto-negotiation 1 = disable auto-negotiation, speed and duplex are R/W 0
decided by bit 6 and 5 of the same register.
0 = auto-negotiation is on.
6Forced speed 1 = forced 100BT if AN is disabled (bit 7). R/W 1
0 = forced 10BT if AN is disabled (bit 7).
KS8995XA Micrel, Inc.
M9999-051305 38 May 2005
Address Name Description Mode Default
5Forced duplex 1 = forced full-duplex if (1) AN is disabled or (2) AN is R/W 0
enabled but failed. For port 4 only,
0 = forced half-duplex if (1) AN is disabled or (2) AN is there is a special
enabled but failed. configure pin to set
the default pin
PCRS strap option.
Pull-down (0):
Force half-duplex.
Pull-up (1):
Force full-duplex.
Note: PCRS has
internal pull down.
4 Advertised flow 1 = advertise flow control capability. R/W 1
control capability 0 = suppress flow control capability from transmission
to link partner.
3Advertised 100BT 1 = advertise 100BT full-duplex capability. R/W 1
full-duplex capability 0 = suppress 100BT full-duplex capability from
transmission to link partner.
2Advertised 100BT 1 = advertise 100BT half-duplex capability. R/W 1
half-duplex capability 0 = suppress 100BT half-duplex capability from
transmission to link partner.
1Advertised 10BT 1 = advertise 10BT full-duplex capability. R/W 1
full-duplex capability 0 = suppress 10BT full-duplex capability from
transmission to link partner.
0Advertised 10BT 1 = advertise 10BT half-duplex capability. R/W 1
half-duplex capability 0 = suppress 10BT half-duplex capability from
transmission to link partner.
Register 29 (0x1D): Port 1 Control 13
Register 45 (0x2D): Port 2 Control 13
Register 61 (0x3D): Port 3 Control 13
Register 77 (0x4D): Port 4 Control 13
Register 93 (0x5D): Port 5 Control 13
Address Name Description Mode Default
7LED off 1 = turn off all port’s LEDs (LEDx_2, LEDx_1, LEDx_0, R/W 0
where “x” is the port number). These pins will be driven
high if this bit is set to one.
0 = normal operation.
6 Txids 1 = disable port’s transmitter. R/W 0
0 = normal operation.
5Restart AN 1 = restart auto-negotiation. R/W 0
0 = normal operation.
4Disable far end fault 1 = disable far end fault detection and pattern transmission. R/W 0
0 = enable far end fault detection and pattern transmission.
3Power down 1 = power down. R/W 0
0 = normal operation.
2 Disable auto MDI/MDI-X 1 = disable auto MDI/MDI-X function. R/W 0
0 = enable auto MDI/MDI-X function.
1Forced MDI 1 = if auto MDI/MDI-X is disabled, force PHY into R/W 0
MDI mode.
0 = do not force PHY into MDI mode.
0MAC loopback 1 = perform MAC loopback. R/W 0
0 = normal operation.
Register 30 (0x1E): Port 1 Status 0
May 2005 39 M9999-051305
KS8995XA Micrel, Inc.
Register 46 (0x2E): Port 2 Status 0
Register 62 (0x3E): Port 3 Status 0
Register 78 (0x4E): Port 4 Status 0
Register 94 (0x5E): Port 5 Status 0
Address Name Description Mode Default
7MDIX status 1 = MDI. RO 0
0 = MDI-X.
6AN done 1 = AN done. RO 0
0 = AN not done.
5Link good 1 = link good. RO 0
0 = link not good.
4 Partner flow 1 = link partner flow control capable. RO 0
control capability 0 = link partner not flow control capable.
3Partner 100BT 1 = link partner 100BT full-duplex capable. RO 0
full-duplex capability 0 = link partner not 100BT full-duplex capable.
2Partner 100BT 1 = link partner 100BT half-duplex capable. RO 0
half-duplex capability 0 = link partner not 100BT half-duplex capable.
1Partner 10BT 1 = link partner 10BT full-duplex capable. RO 0
full-duplex capability 0 = link partner not 10BT full-duplex capable.
0Partner 10BT 1 = link partner 10BT half-duplex capable. RO 0
half-duplex capability 0 = link partner not 10BT half-duplex capable.
Register 31 (0x1F): Port 1 Control 14
Register 47 (0x2F): Port 2 Control 14
Register 63 (0x3F): Port 3 Control 14
Register 79 (0x4F): Port 4 Control 14
Register 95 (0x5F): Port 5 Control 14
Address Name Description Mode Default
7PHY loopback 1 = perform PHY loopback, i.e. loopback MAC’s Tx R/W 0
back to Rx.
0 = normal operation.
6Remote loopback 1 = perform remote loopback, i.e. loopback PHY’s Rx R/W 0
back to Tx.
0 = normal operation.
5 PHY isolate 1 = electrical isolation of PHY from MII and TX+/TX-. R/W 0
0 = normal operation.
4 Soft reset 1 = PHY soft reset. R/W 0
0 = normal operation.
3Force link 1 = force link in the PHY. R/W 0
0 = normal operation.
2-1 Reserved N/A RO 0
0Far end fault 1 = far end fault status detected. RO 0
0 = no far end fault status detected.
Advanced Control Registers
The IPv4 TOS priority control registers implement a fully decoded 64 bit differentiated services code point (DSCP) register used
to determine priority from the 6 bit TOS field in the IP header. The most significant 6 bits of the TOS field are fully decoded into
64 possibilities, and the singular code that results is compared against the corresponding bit in the DSCP register. If the register
bit is a 1, the priority is high; if it is a 0, the priority is low.
Address Name Description Mode Default
Register 96 (0x60): TOS Priority Control Register 0
7-0 DSCP[63:56] R/W 00000000
KS8995XA Micrel, Inc.
M9999-051305 40 May 2005
MIIM Registers
The “PHYAD” defined by IEEE is assigned as “0x1” for port 1, “0x2” for port 2, “0x3” for port 3, “0x4” for port 4, “0x5” for port
5. The “REGAD” supported are 0,1,2,3,4,5.
Address Name Description Mode Default
Register 0: MII Control
15 Soft reset 1 = PHY soft reset. RO 0
0 = normal operation.
14 Loop back 1 = loop back mode (loop back at PHY). R/W 0
0 = normal operation.
13 Force 100 1 = 100Mbps. R/W 1
0 = 10Mbps.
12 AN enable 1 = auto-negotiation enabled. R/W 1
0 = auto-negotiation disabled.
11 Power down 1 = power down. R/W 0
0 = normal operation.
10 Isolate Not supported. RO 0
Address Name Description Mode Default
Register 97 (0x61): TOS Priority Control Register 1
7-0 DSCP[55:48] R/W 00000000
Register 98 (0x62): TOS Priority Control Register 2
7-0 DSCP[47:40] R/W 00000000
Register 99 (0x63): TOS Priority Control Register 3
7-0 DSCP[39:32] R/W 00000000
Register 100 (0x64): TOS Priority Control Register 4
7-0 DSCP[31:24] R/W 00000000
Register 101 (0x65): TOS Priority Control Register 5
7-0 DSCP[23:16] R/W 00000000
Register 102 (0x66): TOS Priority Control Register 6
7-0 DSCP[15:8] R/W 00000000
Register 103 (0x67): TOS Priority Control Register 7
7-0 DSCP[7:0] R/W 00000000
Registers 104 to 109 define the switching engine’s MAC address. This 48-bit address is used as the source address in MAC pause control frames.
Register 104 (0x68): MAC Address Register 0
7-0 MACA[47:40] R/W 0x00
Register 105 (0x69): MAC Address Register 1
7-0 MACA[39:32] R/W 0x10
Register 106 (0x6A): MAC Address Register 2
7-0 MACA[31:24] R/W 0xA1
Register 107 (0x6B): MAC Address Register 3
7-0 MACA[23:16] R/W 0xff
Register 108 (0x6C): MAC Address Register 4
7-0 MACA[15:8] R/W 0xff
Register 109 (0X6D): MAC Address Register 5
7-0 MACA[7:0] R/W 0xff
May 2005 41 M9999-051305
KS8995XA Micrel, Inc.
Address Name Description Mode Default
9Restart AN 1 = restart auto-negotiation. R/W 0
0 = normal operation.
8Force full-duplex 1 = full-duplex. R/W 0
0 = half-duplex.
7Collision test Not supported. RO 0
6Reserved RO 0
5Reserved RO 0
4Force MDI 1 = force MDI. R/W 0
0 = normal operation.
3Disable auto MDIX 1 = disable auto MDI-X. R/W 0
0 = normal operation.
2Disable far end fault 1 = disable far end fault detection. R/W 0
0 = normal operation.
1Disable transmit 1 = disable transmit. R/W 0
0 = normal operation.
0Disable LED 1 = disable LED. R/W 0
0 = normal operation.
Register 1: MII Status
15 T4 capable 0 = not 100 BASET4 capable. RO 0
14 100 Full capable 1 = 100BASE-TX full-duplex capable. RO 1
0 = not capable of 100BASE-TX full-duplex.
13 100 Half capable 1 = 100BASE-TX half-duplex capable. RO 1
0 = not 100BASE-TX half-duplex capable.
12 10 Full capable 1 = 10BASE-T full-duplex capable. RO 1
0 = not 10BASE-T full-duplex capable.
11 10 Half capable 1 = 10BASE-T half-duplex capable. RO 1
0 = not 10BASE-T half-duplex capable.
10-7 Reserved RO 0
6Preamble suppressed Not supported. RO 0
5AN complete 1 = auto-negotiation complete. RO 0
0 = auto-negotiation not completed.
4 Far end fault 1 = far end fault detected. RO 0
0 = no far end fault detected.
3AN capable 1 = auto-negotiation capable. RO 1
0 = not auto-negotiation capable.
2 Link status 1 = link is up. RO 0
0 = link is down.
1Jabber test Not supported. RO 0
0 Extended capable 0 = not extended register capable. RO 0
Register 2: PHYID HIGH
15-0 Phyid high High order PHYID bits. RO 0x0022
Register 3: PHYID LOW
15-0 Phyid low Low order PHYID bits. RO 0x1450
Register 4: Advertisement Ability
15 Next page Not supported. RO 0
14 Reserved RO 0
13 Remote fault Not supported. RO 0
12-11 Reserved RO 0
KS8995XA Micrel, Inc.
M9999-051305 42 May 2005
Address Name Description Mode Default
10 Pause 1 = advertise pause ability. R/W 1
0 = do not advertise pause ability.
9Reserved R/W 0
8Adv 100 Full 1 = advertise 100 full-duplex ability. R/W 1
0 = do not advertise 100 full-duplex ability.
7Adv 100 Half 1 = advertise 100 half-duplex ability. R/W 1
0 = do not advertise 100 half-duplex ability.
6 Adv 10 Full 1 = advertise 10 full-duplex ability. R/W 1
0 = do not advertise 10 full-duplex ability.
5Adv 10 Half 1 = advertise 10 half-duplex ability. R/W 1
0 = do not advertise 10 half-duplex ability.
4-0 Selector field 802.3 RO 00001
Register 5: Link Partner Ability
15 Next page Not supported. RO 0
14 LP ACK Not supported. RO 0
13 Remote fault Not supported. RO 0
12-11 Reserved RO 0
10 Pause Link partner pause capability. RO 0
9Reserved RO 0
8 Adv 100 full Link partner 100 full capability. RO 0
7Adv 100 half Link partner 100 half capability. RO 0
6Adv 10 full Link partner 10 full capability. RO 0
5 Adv 10 half Link partner 10 half capability. RO 0
4-0 Reserved RO 00000
May 2005 43 M9999-051305
KS8995XA Micrel, Inc.
Absolute Maximum Ratings(1)
Supply Voltage
(VDDAR, VDDAP, VDDC)............................. –0.5V to +2.4V
(VDDAT, VDDIO)........................................ –0.5V to +4.0V
Input Voltage (All Inputs) ............................. –0.5V to +4.0V
Output Voltage (All Outputs) ....................... –0.5V to +4.0V
Lead Temperature (soldering, 10 sec.) ..................... 270°C
Storage Temperature (TS) ....................... –55°C to +150°C
Operating Ratings(2)
Supply Voltage
(VDDAR, VDDAP, VDDC)............................. +1.7V to +1.9V
(VDDAT)................... +3.15V to +3.45V or +2.4V to +2.6V
(VDDIO)................................................ +3.15V to +3.45V
Ambient Temperature (TA)
Commercial .............................................. –0°C to +70°C
Package Thermal Resistance(3)
PQFP (θJA) No Air Flow ................................. 42.91°C/W
Electrical Characteristics(4, 5)
Symbol Parameter Condition Min Typ Max Units
100BASE-TX Operation All Ports 100% Utilization
IDDC
100BASE-TX (Digital Core/PLL + Analog RX)
VDDC, VDDAP, VDDAR 194 206 mA
IDDIO 100BASE-TX (Digital IO + Transmitter) VDDIO, VDDAT 223 226 mA
10BASE-TX Operation All Ports 100% Utilization
IDDC 10BASE-TX (Digital Core + Analog RX) VDDC, VDDAP 152 161 mA
IDDIO 10BASE-TX (Digital IO + Transmitter) VDDIO, VDDAT 336 347 mA
Auto-Negotiation Mode
IDDC 10BASE-TX (Digital Core + Analog RX) VDDC, VDDAP 137 146 mA
IDDIO 10BASE-TX (Digital IO + Transmitter) VDDIO, VDDAT 21 23 mA
TTL Inputs
VIH Input High Voltage +2.0 V
VIL Input Low Voltage +0.8 V
IIN Input Current VIN = GND ~ VDDIO –10 10 µA
(Excluding Pull-up/Pull-down)
TTL Outputs
VOH Output High Voltage IOH = –8mA +2.4 V
VOL Output Low Voltage IOL = 8mA +0.4 V
|IOZ|Output Tri-State Leakage 10 µA
100BASE-TX Transmit (measured differentially after 1:1 transformer)
VOPeak Differential Output Voltage
100 termination on the differential output
0.95 1.05 V
VIMB Output Voltage Imbalance
100 termination on the differential output
2%
tr, ttRise/Fall Time 3 5 ns
Rise/Fall Time Imbalance 0 0.5 ns
Notes:
1. Exceeding the absolute maximum rating may damage the device.
2. The device is not guaranteed to function outside its operating rating. Unused inputs must always be tied to an appropriate logic voltage level (ground
to VDD).
3. No heat spreader in package.
4. Specification for packaged product only.
5. Measurements were taken with operating ratings.
KS8995XA Micrel, Inc.
M9999-051305 44 May 2005
Symbol Parameter Condition Min Typ Max Units
100BASE-TX Transmit (measured differentially after 1:1 transformer)
Duty Cycle Distortion ±0.5 ns
Overshoot 5%
VSET Reference Voltage of ISET 0.5 V
Output Jitters Peak-to-peak 0.7 1.4 ns
10BASE-T Receive
VSQ Squelch Threshold 5MHz square wave 400 mV
10BASE-T Transmit (measured differentially after 1:1 transformer) VDDAT = 2.5V
VPPeak Differential Output Voltage 100 termination on the differential output 2.3 V
Jitters Added 100 termination on the differential output 16 ns
Rise/Fall Times 28 30 ns
May 2005 45 M9999-051305
KS8995XA Micrel, Inc.
Timing Diagrams
SCL
SDA
tcyc1ts1 th1
Receive Timing
Figure 11. EEPROM Interface Input Receive Timing Diagram
SCL
SDA
tcyc1
Transmit Timing
tov1
Figure 12. EEPROM Interface Output Transmit Timing Diagram
Symbol Parameter Min Typ Max Units
tCYC1 Clock Cycle 16384 ns
tS1 Set-Up Time 20 ns
tH1 Hold Time 20 ns
tOV1 Output Valid 4096 4112 4128 ns
Table 7. EEPROM Timing Parameters
KS8995XA Micrel, Inc.
M9999-051305 46 May 2005
tcyc2ts2 th2
MTXC
MTXEN
MTXD[0]
Receive Timing
Figure 13. SNI Input Timing
MRXC
MRXDV
tcyc2
Transmit Timing
tov2
MRXD[0]
MCOL
Figure 14. SNI Output Timing
Symbol Parameter Min Typ Max Units
tCYC2 Clock Cycle 100 ns
tS2 Set-Up Time 10 ns
tH2 Hold Time 0ns
tO2 Output Valid 036ns
Table 8. SNI Timing Parameters
May 2005 47 M9999-051305
KS8995XA Micrel, Inc.
MRXCLK
MTXEN
MTXER
MTXD[3:0]
tcyc3ts3 th3
Receive Timing
Figure 15. MAC Mode MII Timing Data Received from MII
MTXCLK
MRXDV
MRXD[3:0]
tcyc3
Transmit Timing
tov3
Figure 16. MAC Mode MII Timing Data Transmitted from MII
Symbol Parameter Min Typ Max Units
tCYC3 Clock Cycle (100BASE-T) 40 ns
tCYC3 Clock Cycle (10BASE-T) 400 ns
tS3 Set-Up Time 10 ns
tH3 Hold Time 5ns
tOV3 Output Valid 71116ns
Table 9. MAC Mode MII Timing Parameters
KS8995XA Micrel, Inc.
M9999-051305 48 May 2005
MTXCLK
MTXEN
MTXER
MTXD[3:0]
tcyc4ts4 th4
Receive Timing
Figure 17. PHY Mode MII Timing Data Received from MII
MRXCLK
MRXDV
MRXD[3:0]
tcyc4
Transmit Timing
tov4
Figure 18. PHY Mode MII Timing Data Transmitted from MII
Symbol Parameter Min Typ Max Units
tCYC4 Clock Cycle (100BASE-T) 40 ns
tCYC4 Clock Cycle (10BASE-T) 400 ns
tS4 Set-Up Time 10 ns
tH4 Hold Time 0ns
tOV4 Output Valid 18 25 28 ns
Table 10. PHY Mode MII Timing Parameters
May 2005 49 M9999-051305
KS8995XA Micrel, Inc.
tsr
tcs tch
trc
Supply
Voltage
RST_N
Strap-In
Value
Strap-In /
Output Pin
Figure 19. Reset Timing
Symbol Parameter Min Typ Max Units
tSR Stable Supply Voltages to Reset High 10 ms
tCS Configuration Set-Up Time 50 ns
tCH Configuration Hold Time 50 ns
tRC Reset to Strap-In Pin Output 50 ns
Table 11. Reset Timing Parameters
Reset Circuit Diagram
Micrel recommendeds the following discrete reset circuit as shown in Figure 20 when powering up the KS8895XA device. For
the application where the reset circuit signal comes from another device (e.g., CPU, FPGA, etc), we recommend the reset circuit
as shown in Figure 21.
VCC
R
10k
D2
C
10µF
D1
CPU/FPGA
RST_OUT_n
KS8995X
RST
D1, D2: 1N4148
Figure 20. Recommended Reset Circuit.
VCC
R
10k
C
10µF
D1
KS8995X
RST
D1: 1N4148
Figure 21. Recommended Circuit for Interfacing with CPU/FPGA Reset
At power-on-reset, R, C, and D1 provide the necessary ramp rise time to reset the Micrel device. The reset out from CPU/FPGA
provides warm reset after power up. It is also recommended to power up the VDD core voltage earlier than VDDIO voltage.
At worst case, the both VDD core and VDDIO voltages should come up at the same time.
KS8995XA Micrel, Inc.
M9999-051305 50 May 2005
Selection of Isolation Transformer(1)
One simple 1:1 isolation transformer is needed at the line interface. An isolation transformer with integrated common-mode
choke is recommended for exceeding FCC requirements. The following table gives recommended transformer characteristics.
Characteristics Name Value Test Condition
Turns Ratio 1 CT : 1 CT
Open-Circuit Inductance (min.) 350µH100mV, 100kHz, 8mA
Leakage Inductance (max.) 0.4µH1MHz (min.)
Inter-Winding Capacitance (max.) 12pF
D.C. Resistance (max.) 0.9
Insertion Loss (max.) 1.0dB 0MHz to 65MHz
HIPOT (min.) 1500Vrms
Note:
1. The IEEE 802.3u standard for 100BASE-TX assumes a transformer loss of 0.5dB. For the transmit line transformer, insertion loss of up to 1.3dB can
be compensated by increasing the line drive current by means of reducing the ISET resistor value.
The following transformer vendors provide compatible magnetic parts for Micrel’s device:
4-Port Integrated Auto Number Single-Port Auto Number
Vendor Part MDIX of Ports Vendor Part MDIX of Ports
Pulse H1164 Yes 4 Pulse H1102 Yes 1
Bel Fuse 558-5999-Q9 Yes 4 Bel Fuse S558-5999-U7 Yes 1
YCL PH406466 Yes 4 YCL PT163020 Yes 1
Transpower HB826-2 Yes 4 Transpower HB726 Yes 1
Delta LF8731 Yes 4 Delta LF8505 Yes 1
LanKom SQ-H48W Yes 4 LanKom LF-H41S Yes 1
Table 12. Qualified Magnetics Lists
May 2005 51 M9999-051305
KS8995XA Micrel, Inc.
Package Information
128-Pin PQFP (PQ)
MICREL INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com
This information furnished by Micrel in this data sheet is believed to be accurate and reliable. However no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2003 Micrel, Incorporated.