AC/DC Converter
www.recom-power.com REV.: 2/2018 PA-5
RAC20-K
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/Video, information and communication technology equipment -
Safety requirements E224736 UL62368-1, 2nd Edition, 2014
CAN/CSA C22.2 Nr. 62368-1-14, 2nd Ed. 201
4
Audio/Video, information and communication technology equipment -
Safety requirements
(CB Scheme)
E491408-A6002-CB-1
IEC62368-1:2014 2nd Edition
EN62368-1:2014 + A11:2017
Household and similar electrical appliances – Safety – Part 1:
General requirements pending
IEC60335-1:2010 + AMD2:2016 + COR1:2016
EN60335-1:2012 + A11:2014 + A13:2017
RoHS 2 RoHS-2011/65/EU
EMC Compliance Condition Standard / Criterion
Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC)
IEC/EN61204-3:2000, Class B
Electromagnetic compatibility of multimedia equipment - Emission requirements
without external filter
Electromagnetic compatibility of household appliances, electric tools and similar
apparatus - Emission Requirements EN55014-1:2006+A2:2011
Information technology equipment - Immunity characters - Limits and methods of
measurement
EN55024:2010 + A1:2015
Electromagnetic compatibility of household appliances, electric tools and similar
apparatus - Immunity Requirements EN55014-2:2015
ESD Electrostatic discharge immunity test
Air: ±2, 4, 8kV, Contact: ±2, 4kV
EN61000-4-2:2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test 10V/m, 3V/m, 1V/m
EN61000-4-3:2006 + A1:2008, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±2.0kV
DC Output Port: ±2.0kV EN61000-4-4:2012, Criteria B
Surge Immunity AC Power Port: L-N ±1.0kV
DC Output Port: ±0.5kV EN61000-4-5:2014+A1:2017, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port: 10V
DC Output Port: 10V EN61000-4-6:2014, Criteria A
Power Magnetic Field Immunity 50Hz, 30A/m EN61000-4-8:2010, Criteria A
Voltage Dips and Interruptions
Voltage Dips 20%
Voltage Dips 30%
Voltage Dips 60%
Voltage Dips 100%
Voltage Interruptions > 95%
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria B
EN61000-4-11:2004+A1:2017, Criteria C
continued on next page
-20-40 0 20 40 60 80 100
100
80
60
40
90
70
50
30
20
10
0
Ambient Temperature [°C]
55 85
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
80
60
40
90
70
50
30
20
10
0
Input Voltage [VAC]
85 90 264
Line Derating