SPECIFICATION
100W Constant Voltage + Constant Current LED Driver HVG-100 series
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
0.38A / 347VAC 0.28A / 480VAC
<0.75mA / 480VAC
95 ~ 108%
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
174.9K hrs min. MIL-HDBK-217F (25 )℃
236*68*38.8mm (L*W*H)
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
SHORT CIRCUIT
18 ~ 21V 28 ~ 34V23 ~ 27V 34 ~ 38V 41 ~ 46V 54 ~ 60V
47 ~ 53V 59 ~ 65V
89% 91% 91% 91%90.5% 91%
±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0%
±0.5%
±0.5%
±1.0%
±0.5%
±0.5%
15V
HVG-100-15 HVG-100-20 HVG-100-24 HVG-100-30 HVG-100-36 HVG-100-42 HVG-100-48 HVG-100-54
24V 30V 48V
150mVp-p 150mVp-p
13.5 ~ 17V 17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V
54V
200mVp-p
49 ~ 58V
42V
200mVp-p
38 ~ 46V
Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
Shut down o/p voltage with auto-recovery or re-power on to recovery
2.75 ~ 5A 2.64 ~ 4.8A 2.2 ~ 4A 1.76 ~ 3.2A 1.45 ~ 2.65A 1.1 ~ 2A 0.97 ~ 1.77A
1.25 ~ 2.28A
5A 3.2A 2.65A 2A
75W 96W 96W 95.4W 96W
1.77A
95.58W
2.28A
95.76W
1.18Kg; 12pcs/15.2Kg/0.74CUFT
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
UL8750(type”HL”), CSA C22.2 No. 250.0-08, EAC TP TC 004 IP65 or IP67 approved,
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
90% 90.5%
20V 36V
4.8A 4A
96W
Compliance to EN55015, EN61000-3-2 Class C ( 50% load, 60% only for 15V model) ; EN61000-3-3, FCC Part 15 Subpart B,≧≧ EAC TP TC 020@ load @ load
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level surge immunity Line-Earth 4KV, Line-Line 2KV , EAC TP TC 020()
EMC IMMUNITY
EMC EMISSION
COLD START 25A(t =900 s measured at 50% I ) at 480VAC;
width peak Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 480VAC
CONSTANT CURRENT REGION
Note.4
9~15V 10~20V 12~24V 15~30V 18~36V 21~42V 24~48V 27~54V
THD< 20%(@ load 50%/230VAC, 277VAC, 347VAC [@ load 60% only for 15V model]; @ load 75%/480VAC)≧≧≧
(Please refer to “TOTAL HARMONIC DISTORTION ” section)(THD)
File Name:HVG-100-SPEC 2018-09-30
Adjustable for A/AB-Type only (via the built-in potentiometer)
Adjustable for A/AB-Type only (via the built-in potentiometer)
SETUP, RISE TIME Note.6
30ms/347VAC, 480VAC
500ms, 80ms /230VAC, 347VAC, 480VAC
180 ~ 528VAC 254VDC ~ 747VDC
(Please refer to "STATIC CHARACTERISTIC" section)
PF 0.98/230VAC, PF 0.98/277VAC, PF 0.97/347VAC, PF 0.93/480VAC @full load≧≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
Tcase=-40 ~ +90 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)℃
MAX. CASE TEMP. Tcase=+90℃
1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
11. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf