767
Related Information
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Head-separated Dual Display Digital Pressure Sensor For Gas
DPS-400 SERIES DPH-100 SERIES
Thin body controller can do cascade connection and
communication with upper devices
Works like a ber sensor
Current value and threshold value can be checked simultaneously on the dual display
DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of
sensorsfordownsizingequipment,convenientshapetotintomachines,andreductionofman-hourswhenitcomes
to replacement.
The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while
checking the “current value (current pressure value)”, direct setting and checking of the “threshold value” is made
smoothly without having to switch screen modes.
Sensor head DPH-100 series
Thin body (t10 mm t0.394
in) and multi-unit connection
on a DIN rail helps to
downsize equipment for better
construction.
Controller DPS-400 series
Digital
General terms and conditions ............. F-7 Sensor selection guide ................. P.731~
Glossary of terms
........................ P.1469~
General precautions
...................... P.1472
Conforming to
EMC Directive
Direct installation using a
hexagonalwrench
●Direct mounting from above
●Installation in narrow spaces
●Extendedfreedomoflayout
●Singleaxistypefreeturning
structure
Install on a DIN rail
“The current value” and “the threshold value” can be checked simultaneously!
Because direct
setting is possible
Operation
is as easy
as analog
Dual display + Direct setting
Thickness
10 mm
0.394 in
Threshold value Current value
panasonic.net/id/pidsx/global
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
768
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Network communication
Connection to CC-Link open network is possible
through the communication unit for CC-Link SC-GU2-C.
Monitoring or setting changes can be carried out via a
PLC, PC, etc.
Ultra high-speed response time at 150 μs
Ultra high-speed response time contributes to even
greater productivity.
Independent dual outputs and ve output modes equipped
The sensor is equipped with two independent
comparative outputs in which separate sensing modes
can be selected.
Wire-saving, space-saving
The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block
setup can be reduced and valuable space is saved. Also, DPS-400seriescanbeconnectedside-by-sidewithber
sensors FX-300 series or laser sensors LS-400 series.
Up to 16 sensors can be connected togetther
DPS-400 series DPS-400 series
Fiber sensor
FX-300 series
Wire-saving in power supply*
DPS-400, FX-300, LS-400, etc.
Power
supply cable
Main cable CN-74-CSub cable CN-72-C
Output line 1
Output line 2 Output line 2’ Output line 16 Output line 16’
Output line 3 Output line 3’
Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained.
Up to 16 sensors allowed in optical communication / setting copying
Wire-saving in power supply
Optical communication / setting copying
* Check the instruction manual of each model for the arrangement order and such when
connecting, as communication varies depending on the model.
Conguresensorsettingstoeachobject
through communications
by remote commands
Object A
Threshold value
Current pressure value
Object B Object C
Response time at 150 μs
EASY mode
This mode is used for comparative output ON / OFF control.
Hysteresis mode
This mode is used for setting comparative output hysteresis
to the desired level and for carrying out ON / OFF control.
Window comparator mode
This mode is used for setting comparative output ON or OFF
at pressures within the setting range.
Forced output ON mode
The comparative outputs are forcibly maintained at ON
irrespective of the set values.
Forced output OFF mode
The comparative outputs are forcibly maintained at OFF
irrespective of the set values.
769
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Large space
needed to turn
the spanner!
Previous problem
Turns minimally
from above!
Spanner cannot
be turned!
Previous problem
Spanner is difcult to hold!
(Obstructedbyoorsurface)
Previous problem
Obstacle
Hexagonal wrench installation saves man-hours and spaces
Usingahexagonalwrench,obstructionscanbeavoidedandinstallationcanbedoneeasilybyturningtheboltfrom
above.
Quick maintenance
During maintenance, the sensor head needed to be
removed can be easily removed from directly above.
Mounting shape at 14 mm 0.551 in
Because the dead zone caused by the nut is eliminated,
the narrowed-down thickness after installation
contributes to space saving.
DPH-100
Remove and install the required sensor head
directly.
Wasted
space
Saved space
12.5 mm
0.492 in
10 mm
0.394 in
75 mm
2.953 in
60 mm
2.362 in
20 % DOWN
from previous
models
14 mm 0.551 in
Previous models
Previous
models
DPH-10□-M3
DPH-10□-M5
DPH-100
DPH-100
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
770
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Type Appearance Rated pressure
range Model No. Pressure port Applicable
uid
Compound
pressure
–100.0 kPa to
+100.0kPa
DPH-101 R1/8malethread+M5femalethread
Air,
non-corrosive gas
DPH-101-M3 M3 male thread
DPH-101-M5 M5 male thread
Flexible
cable type
DPH-101-R R1/8malethread+M5femalethread
DPH-101-M3-R M3 male thread
DPH-101-M5-R M5 male thread
Positive pressure 0to+1.000MPa
DPH-102 R1/8malethread+M5femalethread
DPH-102-M5 M5 male thread
Flexiblecabletype
DPH-102-M5-R M5 male thread
Vacuum pressure
0 to –101.0 kPa
DPH-103 R1/8malethread+M5femalethread
DPH-103-M3 M3 male thread
DPH-103-M5 M5 male thread
Flexible
cable type
DPH-103-R R1/8malethread+M5femalethread
DPH-103-M3-R M3 male thread
DPH-103-M5-R M5 male thread
Sensor heads
DPH-10
-M3(-R)
DPH-10
-M5(-R)
DPH-10
□(
-R)
Type Appearance Model No. Applicable
sensor head Output Connection
method
For compound pressure /
vacuum pressure
DPS-401 DPH-101□
DPH-103□ NPN open-collector
transistor two outputs
Use optional
quick-connection cable
(4-core)
For positive
pressure DPS-402 DPH-102□
Controllers
Quick-connection cables Quick-connection cable is not supplied with the controller. Please order it separately.
End plates End plates are not supplied with the controller. Please order them separately when the controllers are mounted in cascade.
Appearance Model No. Description
MS-DIN-E
When cascading multiple controllers, or when it moves depending on the way it is
installed on a DIN rail, these end plates clamp controllers into place on both sides. Make
sure to use end plates when cascading multiple controllers together.
ORDER GUIDE
Controller mounting
bracket
MS-DIN-2
Controller
protection seal
FX-MB1
Communication
window seal
Connector seal
OPTIONS
Designation Model No. Description
Controller mounting bracket
MS-DIN-2 Mounting bracket for controller
Controller
protection seal FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
controller, as well as, prevents effect on another controller.
Connector seal:
It prevents contact of any metal, etc., with the pins of the
quick-connection cable.
5 m 16.404 ft cable length type
5 m 16.404 ft cable length type (standard: 2 m 6.562 ft)isalsoavailable.Whenorderingthistype,sufx“-C5” to the Model No.
(e.g.) 5 m 16.404 ft cable length type of DPH-103-M5-R is “DPH-103-M5-R-C5
Type Appearance Model No. Description
Main cable
(4-core)
CN-74-C1 Length: 1 m 3.281 ft 0.2 mm2 4-core cabtyre cable,
with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-74-C2 Length: 2 m 6.562 ft
CN-74-C5 Length: 5 m 16.404 ft
Sub cable
(2-core)
CN-72-C1 Length: 1 m 3.281 ft 0.2 mm2 2-core cabtyre cable,
with connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-72-C2 Length: 2 m 6.562 ft
CN-72-C5 Length: 5 m 16.404 ft
771
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
SPECIFICATIONS
Notes:1)Wheremeasurementconditionshavenotbeenspeciedprecisely,theconditionsusedwereanambienttemperatureof+25°C+77°F.
2) The sensor head can be used independently.
3)ModelNo.havingthesufx“-R”isexiblecabletype.
4) Connectors (e-CON) are available as spare parts. CN-EP2: 5 pcs.
Item
Type Compound pressure Positive pressure Vacuum pressure
±100 kPa type 1 MPa type –101 kPa type
Model No. (Note 3)
DPH-101(-R)
DPH-101-M3(-R)DPH-101-M5(-R)
DPH-102
DPH-102-M5(-R)
DPH-103(-R)
DPH-103-M3(-R)DPH-103-M5(-R)
Type of pressure Gauge pressure
Rated pressure range –100.0to+100.0kPa 0to+1.000MPa 0 to –101.0 kPa
Pressure withstandability 500 kPa 1.5 MPa 500 kPa
Applicableuid Air, non-corrosive gas
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Ambient temperature 0to+50°C+32to +122°F(Nodewcondensationallowed),Storage:–10to+60°C+14to +140°F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Temperature characteristics Overambienttemperaturerange0to+50°C+32to+122°F:within±2%F.S.ofdetectedpressureat+25°C+77°F
Material Frontcase:PBT,Rearcase:PBT(glassberreinforced),Pressureport:Stainlesssteel(SUS303),O-ring:NBR
Pressure element: Silicon diaphragm, PPS
Cable 0.2 mm2 4-core oil resistant cabtyre cable (Models with “-R”afxedtotheModelNo.haveexible,oil-resistantcabtyrecable)
Cableextension Extensionuptototal10m32.808 ft is possible with 0.2 mm2, or more, cable.
Weight
Net weight DPH-10□(-R):Head10gapprox./Cable40gapprox.,DPH-10□-M3/M5(-R):Head6gapprox./Cable40gapprox.
Gross weight DPH-10□(-R):80gapprox.,DPH-10□-M3/M5(-R):70gapprox.
Accessory Connector (e-CON): 1 pc. (Note 4)
Sensor heads
Controllers
Type For compound pressure / vacuum pressure For positive pressure
Item Model No. DPS-401 DPS-402
Applicable sensor head Compound pressure : DPH-101
Vacuum pressure : DPH-103Positive pressure : DPH-102
Rated pressure range Compoundpressure:–100.0to+100.0kPa
Vacuum pressure: 0 to –101.0 kPa Positivepressure:0to+1.000MPa
Display / set pressure range Compoundpressure:–199.9to+199.9kPa
Vacuumpressure:+101.3to–101.3kPa Positivepressure:–1.050to+1.050MPa
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption
(Note 2)
Normal operation: 650 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
ECO mode: 500 mW or less (Current consumption 20 mA or less at 24 V supply voltage)
Sensor head supply voltage Same as supply voltage
Sensor head input Input voltage range: 1 to 5 V DC (over rated pressure range)
Comparative outputs
(Comparative output 1, 2)
Output operation NO / NC, selectable by jog switch
Hysteresis Minimum 0 digit, variable by hysteresis setting
Repeatability
With compound pressure type connected: within ±0.2 % F.S. (±4 digits), With vacuum / positive pressure type connected: within ±0.2 % F.S. (±2 digits)
Response time 150μs,500μs,1ms,5ms,10ms,50ms,100ms,500ms,selectablebyjogswitch
Ambient temperature
–10to+50°C+14to+122°F(cascading8to16controllers:–10to+45°C+14to+133°F)(Nodewcondensationoricingallowed),Storage:–20to+70°C 4to+158°F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Temperature characteristics Overambienttemperaturerange–10to+50°C+14to+122°F:within±0.5%F.S.ofpressureat+25°C+77°F
Material Enclosure: Heat-resistant ABS, Protective cover: Polycarbonate, Jog switch: ABS, MODE key: Acrylic
Weight Netweight:20gapprox.
Notes:1)Wheremeasurementconditionshavenotbeenspeciedprecisely,theconditionsusedwereanambienttemperatureof+20°C+68°F.
2)Excludingcurrentconsumptionoftheapplicablepressuresensorhead.
3)25mAmax.if5ormorecontrollersareconnectedtogether.
4) In case of using the quick-connection cable (cable length: 5 m 16.404 ft)(optional)
5) The cable for controller connection is not supplied as an accessory. Make sure to use the quick-connection cables (optional) given below.
Main cable (4-core): CN-74-C1 (cable length: 1m 3.281 ft), CN-74-C2 (cable length: 2 m 6.562 ft), CN-74-C5 (cable length: 5 m 16.404 ft)
Sub cable (2-core): CN-72-C1 (cable length: 1m 3.281 ft), CN-72-C2 (cable length: 2 m 6.562 ft), CN-72-C5 (cable length: 5 m 16.404 ft)
6)Thevaluesspeciedaboveareappliedonlytothecontroller.
NPN open-collector transistor
•Maximumsinkcurrent:50mA(Note3)
•Appliedvoltage:30VDCorless
(between comparative output and 0 V)
•Residualvoltage:1.5Vorless(Note4)[at50mA(Note3)sinkcurrent]
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
772
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Analog voltage
input
Model
discrimination signal
0 V
Terminal No.
+V
Comparative
output 1 Comparative output 2
0 V
+V
Sensor head side terminal arrangement
diagram
Analog voltage
input
Model
discrimination signal
0 V
Terminal No.
+V
Comparative
output 1 Comparative output 2
0 V
+V
Quick-connection cable side terminal
arrangement diagram
I/O circuit diagram
Notes:1)Thequick-connectionsubcabledoesnothave+V(brown)and0V
(blue). The power is supplied from the connector of the main cable.
2)25mAmax.if5ormorecontrollersareconnectedtogether.
3) Do not use the controllers in a series (AND) connection.
Terminal No.
Sensor head main circuit
Controller main circuit
12 to 24 V DC
±10 %
Model
discrimination
signal
Analog
voltage
input
(Brown) +V (Note1)
(Black)
Comparative output 1
(White)
Comparative output 2
(Blue) 0 V (Note1) 50 mA max.(Note2)
50 mA max.(Note2)
Load
Load
Sensor head
internal circuit
Controller internal circuit
Users’ circuit
Intermediate cable
Terminal No.
Color code of connector attached cable
D1
ZD1
ZD2
+V
0 V
1 kΩ
D2
ZD3
Symbols … D1, D2 : Reverse supply polarity protection diode
ZD1 to ZD3 : Surge absorption zener diode
I/O CIRCUIT AND WIRING DIAGRAMS
Wiring
•Make sure to use the optional quick-connection cable for
theconnectionofthecontroller.Extensionuptototal50m
164.042 ft (cascading 9 to 16 controllers: 20 m 65.617 ft) is
possible with 0.3 mm
2
, or more, cable. However, in order to
reduce noise, make the wiring as short as possible.
Others
•This product has been developed / produced for
industrial use only.
• Use within the rated pressure range.
•
Donotuseduringtheinitialtransienttime(controller:1sec.approx.,
sensorhead:50msapprox.)afterthepowersupplyisswitchedon.
•Donotapplypressureexceedingthepressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
•Do not insert wires, etc., into the pressure port.
The diaphragm will get damaged and correct operation
shall not be maintained.
Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
The DPH-100 series is designed for use
with air and non-corrosive gas. It cannot
be used with liquid or corrosive and
inammablegases.
PRECAUTIONS FOR PROPER USE Refer to p.1472 for general precautions.
773
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
DPS-401 DPS-402
11
0.433
10
0.394
75
2.953
27.8
1.094
30
1.181
24
0.945
3
0.118 3
0.118
3
0.118
10.5
0.413
3.95
0.156
7
0.276
MODE key
8.4
0.331
2.7
0.106
30.85
1.215
58.7
2.311
12
0.472
Select 1 indicator (Yellow)
Select 2 indicator (Yellow)
Decimal point
mark (Note1)
Digital display (Green / Red)
Jog switch
Communication window
Suitable for 35 mm 1.378 in width DIN rail
Comparative output 1
operation indicator (Orange)
Comparative output 2
operation indicator (Orange)
36.5
1.437
End plate (Optional)
MS-DIN-E
2.75
0.108
4
0.157
3
0.118
M3 (length 18 mm 0.709 in) pan head screws
M3 square nut
5.6
0.220
24.7
0.972
1.6
0.063
32
1.260
60
2.362
15
0.591
3
0.118
Suitable for 35 mm 1.378 in width DIN rail
Material: Polycarbonate
CN-74-C1 CN-74-C2 CN-74-C5 CN-72-C1 CN-72-C2 CN-72-C5
L
3
0.118
7.2
0.283
13.6
0.535
10
0.394
0.2
0.008
10.5
0.413
10
50
1.969
ø3.3 ø0.130 cable
0.394
2.54
0.100
2.54
0.100
2.65
0.104
7
0.276
12
0.472
( )
14
0.551
( )
2.9
0.114
( )
6
0.236
( )
Length L
Model No. Length L
CN-74-C1 1,000 39.370
CN-74-C2 2,000 78.740
CN-74-C5 5,000 196.850
Length L
Model No. Length L
CN-72-C1 1,000 39.370
CN-72-C2 2,000 78.740
CN-72-C5 5,000 196.850
L
1.969
ø3.3 ø0.130 cable
10
0.394
3
0.118
7.2
0.283
13.6
0.535
10
0.394
7
0.276
2.54
0.100
2.54
0.100
2.65
0.104
0.2
0.008
10.5
0.413
12
0.472
( )
14
0.551
( )
2.9
0.114
( )
6
0.236
3
0.118
( )
Note: Decimalpointsforpressurevalue.AbovegureshowstheDPS-401
(compound pressure / vacuum pressure). Positions of display and the
pressure unit on the name plate for DPS-402 (positive pressure) differ
fromtheabovegure.
Controller
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
Main cable (Optional) Sub cable (Optional)
DPH-10□(-R)
Hexagonal hole
(bolt width 5 0.197, 4 0.157 deep)
ø3.7 ø0.146 cable,
(2 m 6.562 ft / 5 m 16.404 ft long)
R 1/8
M5 female thread
13.2
0.520
23.4
0.921
R6.6
R0.260
6.6
0.260
9
0.354
10
0.394
14
0.551
ø8.3
ø0.327
4.8
0.189
7
0.276
5
0.197
Sensor head
DPH-10□-M3(-R) DPH-10□-M5(-R)
DPH-10-M3(-R): M3 male thread
DPH-10-M5(-R): M5 male thread
Hexagonal hole
(bolt width 3 0.118, 3.5 0.138 deep)
ø3.7 ø0.146 cable,
2 m 6.562 ft long
Gasket
A
4.8
0.189
7.8
0.307
R5
R0.197
6.6
0.260
ø8.4
ø0.331
ø6.2
ø0.244
5
0.197
0.5
0.020
14
0.551
20.5
0.807
10
0.394
Sensor head
Model No. A
DPH-10□-M3(-R) 3.5 0.118
DPH-10□-M5(-R)3.5 0.138
Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES
774
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DPC-L100/
DPH-L100
DPS-400/
DPH-100
DPC-100/
DPH-100
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
MS-DIN-2
35
1.378
27
1.063
t 1
t 0.039
0.4
0.016
7.5
0.295 4.2
0.165
2
0.079 2
0.079
ø1.8
ø0.071
2-ø3.2 ø0.126 holes
3.2
0.126
3.2
0.126
5.2
0.205
5.2
0.205
21.6
0.850
16
0.630
5
0.197
10
0.394
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)
8.5
0.335
Controller mounting bracket (Optional)